Skip to content
Practical guide

Exporting a Clean IFC4 Model for MEP and Structural Engineers (Base Point & Classification)

Reliable IFC4 export for Swiss structural and MEP engineers: MN95 georeferenced base point, eCCC-Bât classifications and zero geometry loss.

Table of contents
The 3 Major Site Risks
  1. Financial / Margin: An elevation offset or a corrupted model generates undetected opening clashes, resulting in underpinning work that can incur an illustrative extra cost of around 15 000 CHF to 45 000 CHF under art. 364 CO.
  2. Legal / Parity / SUVA: The erroneous export of structural thicknesses compromises the safety of temporary shoring according to the general planning obligations imposed by art. 3 OTConst.
  3. Administrative / Acceptance: Rejection of the digital coordination model during the compliance check by the site management, preventing the validation of engineering provision openings under standard SIA 118.

This technical guide details the standardized IFC4 export protocols for Swiss architects, technicians, and draftspersons sharing their models with structural engineering and HVAC/MEP specialist firms. Strict spatial data transmission prevents lost objects or volumetric distortions during multidisciplinary model federation on French-speaking Swiss projects.

Geometric alignment requires locking the project base point strictly to the Swiss MN95 national coordinate system and structuring semantic properties according to CRB's eCCC-Bât codes. This approach ensures compliance with the obligations of art. 365 CO during technical exchanges between consultants.

IFC4 export method: MN95 georeferencing and solid preservation

Exporting an architectural model to structural calculation and MEP sizing software demands a rigorous configuration of the IFC4 translator. Standard SIA 118 governs contractual relations between clients, design consultants, and contractors, making spatial error-free digital deliverables indispensable.

The first requirement lies in setting the Project Base Point. Coordinates must align with the Swiss MN95 national survey without shifting the modelling software's internal origin beyond the geometry engine's accuracy limits. Using a local coordinate system linked to the survey point prevents corruption of curved surfaces (B-Rep) and distortion of technical penetrations.

For the structural engineer, the analytical model and load-bearing components must be unambiguously classified as IfcWall, IfcBeam, or IfcSlab with the LoadBearing attribute set to True. For the MEP engineer, provision voids and shafts require precise typing via IfcBuildingElementProxy or IfcOpeningElement, ensuring that spatial intersections match the physical reality of the building without altering the contractor's liability set out in art. 364 CO.

Transfer schema configuration: IFC2x3 vs IFC4

The choice of data schema determines the long-term reliability of structural calculations and thermal assessments carried out by specialist consultants:

Technical criterion IFC2x3 protocol (Coordination View 2.0) IFC4 protocol (Reference View) Impact on MEP and structural engineers
Solid geometry Polygonal faceting of curved elements NURBS surfaces and exact geometries Precise reinforcement and clean core drillings
Geodetic system Manual conversion or X/Y offset Built-in native MN95 georeferencing Exact overlay without manual re-entry
CRB classification Free custom property sets IfcClassification mapped to eCCC-Bât Direct extraction into quotes by CFC
Layer transfer Materials merged into a single solid Layer details via IfcMaterialLayerSet Separate acoustic and structural calculations
Provision voids management Simplified Booleans often unrecognized Standardized, editable opening objects Unambiguous validation of duct routing

Frequent setup errors and induced costs

Incorrect layer assignment or raw export of stray 2D geometries generates heavy files unusable by structural calculation software. Failing to purge non-standardized object families corrupts the IFC database, masking load-bearing boundaries that are essential for formwork sizing.

An elevation discrepancy caused by a zero point improperly tied to the official survey creates the risk of ordering ventilation ducts incompatible with clearances beneath beams. Rectifying such inconsistencies on the construction site leads to administrative delays and material extra costs of around 8 000 CHF to 25 000 CHF to adapt suspended service runs during the construction phase.

Failing to populate the fire-resistance property (Pset_WallCommon.FireRating) stops the safety engineer from verifying compliance, forcing the site management to demand a full model revision under pain of dispute under art. 365 CO.

Illustrative practical cases (typical scenarios on Swiss construction sites)

The figures and scenarios presented below are illustrative examples designed for professional training.

In the canton of Vaud, a three-storey mixed timber-concrete project brought together a team of twelve technicians and engineers. During the initial model exchange, the architecture firm exported an IFC2x3 file without uniform elevation calibration. The structural engineer identified a 24-centimetre vertical offset between the top of slabs and the timber framing bearings, halting load takedown calculations. The team corrected the workflow by switching to an IFC4 Reference View export tied to the official MN95 survey point, systematically assigning the eCCC-Bât code to every load-bearing element. This correction enabled accurate extraction of provision openings for the sanitary engineering consultant without requiring any underpinning work.

In the canton of Fribourg, an engineering office planning a workshop hall for eight trades systematically assigned thermal properties through standardized IFC4 Pset property sets. Interdisciplinary coordination validated floor slab penetrations right from the design phase, avoiding any layout clashes when installing soil and waste stacks.

Surfaces, standards and permits: free tools

SIA 416 floor areas and volumes, cantonal zoning ratios, U-values and dew points, acoustics, planning enquiry requirements.

View engineering tools

Frequently asked questions

Which export schema should you choose to coordinate with the structural engineer?

Choose the IFC4 Design Transfer View schema. It preserves the exact geometry of penetrations in reinforced concrete, avoiding design rework estimated at an illustrative amount of around 4 200 CHF.

How do you georeference the IFC file using the Swiss MN95 system?

Populate the base point with official Swiss coordinates and the federal elevation. This prevents setting-out discrepancies that could lead to disputes under the Code of Obligations (CO).

Why must IfcBuildingElementProxy classes be eliminated?

These generic entities bypass thermal and structural calculation filters. Missing proper classification stalls technical coordination and delays approval of the building's execution drawings.

Which classification should you apply to streamline quantity takeoffs?

Systematically assign eCCC-Bât codes to 3D components. This method structures the property sets required for subsequent quantity surveys and ensures reliable detailed quotes under Swiss standards.

The MEP engineer requests opening provisions: how should voids be exported?

Use the IfcOpeningElement class linked to host walls. This geometric precision prevents unexpected core drillings on the construction site, where extra costs often reach an indicative amount of 6 500 CHF.

How does Swiss law govern digital model errors?

Under the Code of Obligations (CO), architects and engineers are liable for design defects for five years under art. 371 CO governing works contracts and property design consultancy services.

Operational summary for reliable digital models

A rigorous IFC4 export guarantees flawless transmission of built volumes and metadata to specialist consultants. This protocol eliminates vertical setting-out clashes and secures the preparation of tenders right from early project stages.

To expand your knowledge of digital model management and deliverable structuring under Swiss best practice, explore our dedicated technical guides:

Art Construction is an independent company: it is not affiliated with the SIA, CRB, SUVA, or KBOB. Referenced norms and standards point to publications from these bodies; only official versions are legally binding.