Air-to-water heat pump and solar in the canton of Nidwalden: OPB noise, silent mode and the energy act

In the canton of Nidwalden, an air-to-water heat pump close to a neighbour is often settled by its position and its night-time silent mode, before any talk of an enclosure.

Open the free studio →

Free, no account: your data stays in your browser. Indicative results, to be confirmed by the installer and the cantonal office.

The canton of Nidwalden regulates energy through its cantonal energy act (kantonales Energiegesetz, kEnG), revised and in force since 1 November 2021, and through its implementing ordinance (kEnV). The energy compliance documents for a project are submitted with the building permit application to the municipality. The sources consulted do not say whether an outdoor air-to-water heat pump in Nidwalden follows an ordinary permit, a simplified procedure or a notification: ask the municipal building office and the competent cantonal department before you submit. In every case, the federal Noise Abatement Ordinance (OPB, Lärmschutz-Verordnung) applies to a new installation.

The Art Construction heat pump, noise and solar studio prepares the technical calculation in the browser. It sizes the unit according to SIA 384/201, calculates the day and night rating level Lr with the method of Cercle Bruit implementation guide 6.21, taking into account the night-time sound power in silent mode when the manufacturer’s data sheet gives it, and estimates photovoltaic yield. It has no weather station in the canton and no Nidwalden subsidy scale: you enter the location and the official amount yourself.

Worked example: night-time silent mode for a heat pump in Nidwalden

A Nidwalden house heated with oil, with underfloor heating. The location is entered freely at 520 m, with a design temperature of −9 °C and irradiation of 1,150 kWh/m² per year (example values, to be checked). The unit stands against the façade, 5 m from the neighbour’s window, in noise sensitivity level II (example value).

Heat pump, noise and solar: Nidwalden example (example values)
StepInputCalculationResult
Heat demand1,800 l of heating oil, efficiency 0.851,800 × 10 × 0.85 ÷ 2,300 h6.65 kW
Unit selectedoutdoor air-to-water, underfloor 35 °Csmallest template that covers the demand8 kW template (7.8 kW at 35 °C)
Normal night noiseLWA 49 dB(A), façade, 5 m49 − 11 + 6 − 14.0 + 10 + 2Lr = 42.0 dB(A), amber status
Silent mode noiseLWA 45 dB(A)45 − 11 + 6 − 14.0 + 10 + 2Lr = 38.0 dB(A), green status
Solar5 kWp, south 30°5 × 1,150 × 1.12 × 0.845,410 kWh per year

One thousand eight hundred litres of oil at 10 kWh per litre and an efficiency of 0.85 give 15,300 kWh of useful heat; divided by 2,300 full-load hours, that is 6.65 kW. The studio selects the 8 kW unit, which delivers 7.8 kW at 35 °C. With its night sound power of 49 dB(A), against the façade at 5 m: 49 − 11 + 6 − 20 × log(5) + 10 + 2 = 42.0 dB(A). The 3.0 dB margin below 45 dB(A) reaches the precautionary threshold: amber status.

In silent mode, the template’s data sheet gives 45 dB(A) at night: Lr falls to 38.0 dB(A) and the margin rises to 7.0 dB. Silent mode also slightly reduces the output available at night: check with the installer that it remains sufficient in very cold weather. Five kWp facing due south produce about 5,410 kWh per year.

In normal operation, the unit reaches 42.0 dB(A) at night, at the precautionary threshold; in silent mode, it drops to 38.0 dB(A).

3 common mistakes with a heat pump and solar in Nidwalden

Calculating with the daytime sound power

The manufacturer’s data sheet gives several levels: maximum daytime operation, night and silent mode. The night calculation uses the night level actually programmed, and the setting must be verifiable.

Assuming the procedure without asking

The sources consulted do not set the Nidwalden procedure for an outdoor heat pump. Ask the municipality before promising the client a simple notification.

Forgetting the energy compliance documents

In Nidwalden, the energy compliance documents accompany the permit application. Prepare them with the technical file to avoid having it sent back by the municipality.

How to use it in 3 steps: heat pump, noise and solar in Nidwalden

  1. Enter the location and the heating oil
    Choose “Other location”, enter the altitude, design temperature and irradiation of your site, then the oil consumption. The studio proposes the template.
  2. Compare normal night and silent mode
    Place the unit and the neighbour’s window, read the night Lr, then enter the silent mode level from the manufacturer’s data sheet. Compare the two statuses.
  3. Add the solar system and print
    Enter the panels and the household consumption, then print the sheet and the plan. Attach them to the documents requested by the municipality.

Open the free studio →

What the free version does not do for a Nidwalden project

The studio submits no permit application, no notification and no subsidy application. It does not replace the official noise certificate or the installer’s calculation, and it does not know the noise sensitivity level of the plot. It has no weather station and no subsidy scale for Nidwalden: the subsidy application is in principle submitted before work begins, to be checked with the canton.

Soumissions takes the unit and panels into a bid with the price database; the ERP tracks the site and invoicing; Portail chantier files the noise documents and compliance records. The related pages also link to the Geo-Scanner page for the canton of Nidwalden.

Frequently asked questions

Which energy act applies in Nidwalden?

The cantonal energy act (kEnG), revised and in force since 1 November 2021, with its implementing ordinance. The energy compliance documents accompany the building permit application.

Is a permit needed for an outdoor heat pump in Nidwalden?

The sources consulted do not say. Ask the municipal building office whether an ordinary, simplified or notification procedure applies, and prepare the noise calculation in any case.

Is silent mode accepted in the noise calculation?

The calculation may use the night level actually programmed if the manufacturer’s data sheet gives it and the setting is fixed. The studio lets you enter this level; the authority checks the justification.

Do rooftop solar panels have to be notified?

An installation sufficiently adapted to the roof is in principle subject to notification under Article 18a of the Spatial Planning Act (LAT). Cultural monuments and protected sites remain subject to a permit: check with the municipality.