Skip to content
Website
🧱 CFC 282Adhesives, back-buttering and large formatsChapter 3 of 10 in the section

Large formats: suction pads, levelling systems, two-person teamwork and breakage

The handling and installation of large-format ceramic slabs tolerate no improvisation on the construction site. Solo handling or unsuitable tools inevitably lead to the breakage of expensive elements and lippage that does not comply with the SIA 248 standard. This chapter details working in pairs, securing with vacuum suction pads and adjusting with self-levelling spacers.

Key takeaways

  • Handling slabs requires two operators and a rigid transport frame fitted with suction pads.
  • Visual inspection of the vacuum indicator on the pump suction pads prevents any sudden detachment.
  • Self-levelling shims guarantee compliance with the flushness tolerances prescribed by the SIA 248 standard.
  • Trying to handle a large-format slab alone results in financial breakage that is heavier than the time saved.

Secure the lifting and transport of slabs to eliminate the risk of breakage

Large-format ceramic slabs, from 120 × 120 cm or in the form of 100 × 300 cm panels, exhibit very high surface rigidity combined with critical vulnerability to bending. When unloading from the delivery A-frame or moving through the building's corridors, the slightest overhang, jerky acceleration or asymmetrical torsion immediately generates a crack initiation. The very high purchase price of these high-end materials forbids improvisation: the breakage of a single slab wipes out the financial margin of several dozen square metres laid and delays the overall schedule of the construction site. Organisation therefore dictates exclusive handling in a pair equipped and trained in coordinated trajectories.

Vacuum pump suction pad with mechanical indicator
Manual gripping tool equipped with a spring-loaded piston and a flexible elastomer diaphragm. Air depression is established by successive pumping until the red warning line sinks into the pump body. If the diaphragm loses its seal during operation, the red ring reappears immediately, signalling to the installer the obligation to put the slab down or pump again without releasing the load.
  1. Inspection of suction pads and degreasingMeticulously dust the back of the tile. Clean the rubber suction discs and operate the manual pistons until the red indicator ring disappears completely, confirming a level of vacuum sufficient for carrying.
  2. Coordinated lifting from the rackPosition a tiler at each end of the transport frame. Bend the legs and lift the piece in unison while rigorously maintaining the panel in its vertical plane to neutralise destructive transverse stresses.
  3. Secure routing to the installation areaGuide the slab without sudden movements while anticipating obstacles on the floor. The operator positioned at the rear announces narrow passageways and level changes, avoiding any mechanical impact against door frames or protruding corners.
Gripping devices and safety criteria
Type of equipmentField of applicationMandatory inspection
Extendable frame with multiple suction padsSlabs with a length greater than 240 cmCheck the vacuum on each pressure gauge and lock the sliders
Pair of manual pump suction padsSquare elements up to 120 × 120 cmCleanliness of the sealing lips and continuous monitoring of the safety indicator
Mobile trolley with inclined platformHeavy transfer from unloadingWedge the lower stops and fasten the flexible retaining straps

Apply the tile adhesive and adjust the levelling in accordance with SIA 248

The installation of a giant slab precludes late repositioning once contact has been established. The deformable tile adhesive must be applied using the rigorous technique of buttering-floating, with a 10 to 15 millimetre notched trowel with bevelled teeth on the substrate and careful buttering in a continuous layer on the back of the tile. This method guarantees a full and continuous bed without any residual air voids under the ceramics. The absence of cavities prevents subsequent breakage caused by concentrated operating loads or point impacts. The panel is lowered slowly by the two tilers, who use the hold of the suction pads to adjust the trajectory without hitting neighbouring slabs that have already been wedged.

The SIA 248 standard defines the execution requirements for tile coverings, in particular the geometrical flatness tolerances and the strict limits of lippage permitted between two adjacent tiles.

norme SIA 248

Once the slab is in contact with the adhesive bed, the pair proceeds to fully tap down from the centre to the outer edges using a flat beating block or a vibrating trowel. This controlled vibration drives out the air trapped in the grooves and ensures the uniform crushing of the mortar beads. Mechanical levelling systems are used immediately after this initial tightening to lock the edges and correct the slight warping specific to large porcelain stoneware panels.

  • Positioning of the bases: slide the clips under the slab 5 centimetres from the corners, then at regular intervals not exceeding 40 centimetres.
  • Locking with wedges: insert the plastic wedges using the adjustable-force pliers without forcing the adhesive structure.
  • Use of rotating dials: screw on the levelling caps equipped with transparent protective washers to preserve the delicate glazes.
  • Straightedge check: check the installation plane along the diagonals before the mortar begins its hydraulic setting.

Coordination of the pair and inspection of suction pads during transfer

Handling a large-format porcelain stoneware slab tolerates no individual improvisation. As soon as one of the sides exceeds 120 centimetres or the unit surface area crosses the one square metre threshold, the dead weight combined with the low thickness turns the slightest torsion into a crack initiation. Claiming to install such elements alone represents a flawed economic calculation: the breakage of a single rectified tile instantly cancels out the time saved over several hours of work, not to mention supply delays from merchants. Working in pairs constitutes the absolute rule to guarantee the rigidity of the element throughout the approach and placement phase on the tile adhesive bed.

  1. Cleaning and degreasing of the facingPass a dry sponge or a volatile degreaser over the exposed face of the tile at the exact location where the suction discs will rest. Microporosity or surface dust drastically reduces the durability of the mechanical vacuum.
  2. Priming and load checkOperate the piston until the warning line disappears completely. Exert a slight manual test pull to check the grip before lifting the piece off the cutting table or mobile trolley.
  3. Synchronised lifting and vertical holdThe two tilers coordinate their effort by lifting the slab onto its edge. Transport is always carried out in the vertical plane to limit the bending moments induced by gravity, avoiding any jolts when crossing thresholds.
  4. Inclined presentation and air evacuationArrived at the glued area, the pair lowers the piece by first applying a long side. Progressive angled installation prevents air from becoming trapped under the porcelain stoneware, allowing the tile adhesive grooves to crush uniformly in accordance with the requirements of the SIA 248 standard.

Verbal communication between the two installers must punctuate each stage of the transfer. The main installer guides the alignment on the laser mark or the previously placed spacer shims, while the second worker regulates the lowering without releasing the lifting tension. Any jolt, impact against an adjacent edge or insecurely supported footing creates micro-cracks invisible to the naked eye that will burst during subsequent mechanical beating.

Adjustment with the self-levelling system and prevention of residual stresses

The SIA 248 standard specifies the requirements relating to flatness and permissible lippage between neighbouring elements. On large-surface tiles with rectified edges, the slightest misalignment of half a millimetre is immediately perceptible under glancing light. The use of a mechanical levelling system never dispenses with rigorous buttering-floating nor with beating with a vibrating pad or a synthetic rubber beating block; the sole purpose of these shims is to neutralise the factory cupping of the tile and cancel out differential shrinkages of the adhesive bed during its setting.

Technical comparison of mechanical levelling systems for large formats
Clamping deviceTensile forceRisk for the rectified edgeImplementation precautions
Notched plastic wedges with adjustable pliersProgressive and linearLow if the baseplate is cleanAdjust the pliers stop so as not to break the stem under the slab before complete drying.
Rotating dials or screw capsDirect and powerfulMedium in case of direct frictionInsert an anti-scratch washer to avoid marking polished or semi-matt surfaces.
Metal lever and cam stemsVery high and rigidHigh on thin ceramicsTo be reserved for very heavy thicknesses; risk of chipping the glaze on sharpened edges.

The insertion of the levelling bases under the tile must take place immediately after placement in the still-fresh tile adhesive bed. If the adhesive starts to skin over, the sinking of the plastic base creates a void under the edge, compromising local adhesion. The ties are generally positioned between 5 and 10 centimetres from the corners, then at regular intervals of approximately 30 to 40 centimetres along the entire length of the edges. A base should never be positioned directly at the intersection of joints, at the risk of destabilising the common edges.

Once all the elements have been detached and cleared away, the tiler proceeds to inspect the work using a two-metre straightedge and meticulous sweeping of the joints before filling. Any tile adhesive residue that has risen into the joint or become stuck to the side of the ceramic must be scraped off while it remains soft. By scrupulously respecting the separation of roles during lifting, the visual inspection of the suction pads and the measured tightening of the flatness devices, the team delivers a surface without lippage complying with the tolerances of the SIA 248 standard, while avoiding major additional costs linked to the breakage of noble materials.

Management of handling incidents and emergency removal protocol

On a tiling construction site, the breakage of a large-format porcelain stoneware generates financial losses that far exceed the illusory savings of a solo installation. As soon as a cracking sound is heard or a piston suction pad shows a loss of vacuum during transfer, the pair must immediately stop the manoeuvre and place the piece on its handling cradle to prevent clean breakage.

  1. Immediate removal of the defective panelIf the tile cracks upon crushing or shows irrecoverable lippage under the levelling system, the pair re-engages the supporting frame equipped with manual suction pads. Lifting takes place vertically, in a synchronised manner, in order to overcome the suction of the fresh tile adhesive bed without bending the ceramic panel.
  2. Complete cleaning of the adhesive bedThe SIA 248 standard requires an optimal and continuous contact surface under large elements. It is forbidden to simply skim over the crushed area. The tile adhesive on the floor and on the back of the slab must be completely scraped off with a trowel before it forms a surface skin.
  3. Integrity check of lifting toolsBefore engaging a new slab, the team leader inspects the sealing lips of the pump suction pads to track down dust or cutting notches. The control pressure gauges are checked under a vacuum on a clean test surface.

Working in pairs with serviced lifting equipment remains the only method to guarantee compliance with the requirements of the SIA 248 standard. The time invested in calmly repositioning a panel preserves the project's margin, where the breakage of a single large-format piece neutralises the profit of a whole day's work.

Frequently asked questions

What to do when a suction pad loses its vacuum during carrying?

The pair puts the slab down without delay on the transport trolley or on shims placed on the floor. Continuing the movement of a large format on three support points generates a critical overhang that breaks the ceramics. The rubber lip must be inspected, the dusty film on the tile cleaned with a dry cloth, and then pumped again until the red safety indicator of the piston disappears completely.

How to remove a freshly installed large-format panel without breaking it?

The suction of the tile adhesive in buttering-floating offers very strong resistance. One must never pry with a screwdriver on the edges, under penalty of chipping the body. The pair locks the suction pads of the handling frame on the exposed face, then exerts a perfectly vertical and progressive traction while inserting a flat plastic spatula under an edge to break the suction effect of the fresh mortar.

Why does excessive tightening of self-levelling spacers cause breakage?

The oscillating shims or screw dials exert a very high point stress on the rectified edges. If the substrate exhibits an underlying local hollow, the tightening forces the slab to bend beyond its elastic limit, which leads to immediate cracking or internal stresses. The adjustment must accompany the levelling of the tile without ever replacing a homogeneous distribution of the adhesive.

What is the real financial additional cost of a broken large-format slab during installation?

The direct cost includes the purchase value of the tile and express delivery charges. However, the real prejudice also includes the loss of three hours of qualified labour to remove the piece, clear away the rubble, scrape and then mix the tile adhesive again. The immobilisation of the pair on a single piece destroys the yield of the laid surface and inevitably shifts the intervention schedule of other trades.

Texts and standards cited

  • SIA 248Tiled and bonded coverings: execution rules, substrate preparation and double-gluing requirements for ceramic and natural stone coverings.

In the same section