Skip to content
Website
🧱 CFC 282Adhesives, back-buttering and large formatsChapter 4 of 10 in the section

The trowel: notch size according to format, direction of grooves and thickness of flattened adhesive

The choice of notch size directly determines the final thickness of the adhesive mortar bed and the transfer rate under the tiling. An undersized notch leaves major air voids, causing punching failures and debonding. This chapter defines the notch profiles by format and details the rectilinear combing required by SIA 248 to ensure full bedding.

Key takeaways

  • An undersized notch creates air voids under the tile, promoting cracks and premature debonding.
  • The SIA 248 standard mandates complete adhesive mortar transfer, requiring back-buttering (double buttering) for areas from 900 cm² onwards.
  • The grooves must remain strictly rectilinear and parallel to expel air during flattening.
  • The final thickness of the flattened adhesive mortar bed must measure between two and five millimetres.

Size the notch according to the format to guarantee the thickness of the flattened adhesive

The geometry of the notched trowel determines the theoretical volume of adhesive mortar applied per square metre. During the pressing and beating of the tile, the adhesive ridges must collapse completely into the adjacent grooves without leaving gaps. A trowel that is too small relative to the dimensions of the slab prevents this complete volumetric flattening: the mortar fails to compensate for the flatness tolerances of the substrate or the residual warping of the ceramic. This results in a discontinuous bed, burdened with air pockets where the tile remains unsupported, highly vulnerable to concentrated operational loads.

Choice of notch size and application method according to tile format
Ceramic format (side or surface)Application methodRecommended trowel profileIndicative consumptionFinal flattened thickness
Mosaic and formats up to 10 x 10 cmSingle gluingSquare notch 4 x 4 mm or 6 x 6 mm1.5 to 2.5 kg/m²1.5 to 2.0 mm
Medium formats up to 30 x 30 cm (< 900 cm²)Single or double gluingSquare notch 8 x 8 mm3.0 to 4.0 kg/m²2.0 to 3.0 mm
Large formats from 30 x 60 to 60 x 60 cmMandatory double gluingSquare notch 10 x 10 mm or half-moon 15 mm4.5 to 6.0 kg/m²3.0 to 4.0 mm
Extra-large formats (> 60 x 120 cm) and thin slabsTechnical double gluingBevelled notch or half-moon 20 mm + flat trowel6.0 to 8.5 kg/m²3.5 to 5.0 mm

The final thickness of the installation bed after beating must imperatively be between 2 and 5 mm depending on the class of adhesive mortar selected. For large-format slabs, the use of half-moon or bevelled teeth trowels is preferred: their rounded section facilitates the lateral collapse of the beads under moderate pressure, avoiding excessive pushing of mortar into open joints. An adhesive flattened to less than 2 mm no longer compensates for differential movements of the substrate, while a thickness exceeding the manufacturer's limits induces differential hydraulic shrinkage during drying.

Orient the grooves in parallel lines to purge air and ensure a full bed

The compactness of the mortar bed depends entirely on the combing pattern applied to the substrate and the back of the slab. Air trapped under a tile can only escape if the channels formed by the grooves remain open to the outside until the moment of mechanical flattening. Any circular, crossed or rotating trajectory traps sealed air cavities that refuse to purge under the weight or vibrations of beating. These bubbles form areas of zero adhesion conducive to thermal decohesion and bursting under rolling loads.

  1. Contact layer on the substrateApply a thin layer of adhesive mortar with the flat side of the trowel onto the clean screed to saturate the porosity and guarantee chemical bonding.
  2. Rectilinear combingDraw the grooves with the notched trowel in strictly straight and parallel passes, systematically oriented along the shortest side of the tile to minimise the air evacuation distance.
  3. Back-butteringSpread a flat 1 mm layer on the back of the tile with the flat trowel for standard formats, or draw grooves parallel to those on the floor for elements with a surface area greater than 3600 cm².
  4. Clamping and beatingPlace the tile with an offset of a few centimetres, apply pressure perpendicular to the grooves and then beat back and forth to break the ridges and push the air towards the edges.

To validate the suitability of the notch size and the tightening force, the site foreman performs a systematic destructive check during production: the immediate lifting of a freshly beaten tile makes it possible to observe the flattening of the beads. The ridges must be totally destroyed and the back of the tile fully wetted by the binder, attesting to a uniform residual thickness conforming to the technical datasheets of deformable adhesive mortars.

Notch sizing and adhesive thickness correspondence under tiles

The choice of notch size does not respond to workshop habit, but to a rigorous volumetric calculation. The adhesive mortar spread with the notched smoothing trowel forms regular ribs whose collapse under the installation pressure must fill the entire void without leaving air corridors. An excessively weak notch does not deliver the amount of binder required to compensate for dimensional tolerances and the allowable warping of ceramics, making contact discontinuous. Conversely, excessive thickness outside technical specifications causes hydraulic shrinkage tensions and differential unevenness during setting. In accordance with the principles of the SIA 248 standard, the flattened adhesive bed must present a homogeneous density, without breaking load-bearing capacity under operational loads.

Selection of trowel notch and resulting thickness after beating
Tile format (surface or side)Installation techniqueTrowel on substrateAdhesive application on tile backFinal flattened adhesive thickness
Up to 100 cm² (mosaic, small element)Single gluingSquare notch 4 mmNo application1.5 to 2.0 mm
Up to 900 cm² (e.g. 20x20 to 30x30 cm)Single gluing or double gluingSquare notch 6 to 8 mmFine contact buttering (if required)2.0 to 3.0 mm
From 900 to 3600 cm² (e.g. 60x60 cm)Mandatory double gluingSquare notch 10 mm or half-moon 15 mmSquare notch 4 mm or dressed buttering3.0 to 4.5 mm
From 3600 to 10 000 cm² (e.g. 60x120, 90x90 cm)Mandatory double gluingHalf-moon notch 15 to 20 mm or inclined teethSquare notch 4 to 6 mm3.5 to 5.0 mm
Large formats > 1 m² and thin slabsMandatory double gluingSpecific inclined teeth notch 10 to 12 mmSquare notch 3 to 4 mm in tight pass3.0 to 4.5 mm

The morphology of the notch directly influences mechanical indentation resistance. Traditional square-toothed trowels require very significant vertical clamping effort to flatten the mortar ridges, which complicates the task on large-format tiles and increases the risk of residual air pockets. Half-moon or inclined teeth notches are designed to tilt and spread laterally at the slightest vibrational pressure. This mechanical sliding promotes the continuous fusion of the adhesive beads with each other, making it possible to obtain the required residual thickness without excessively straining the tile or tiring the operator during striking.

Rectilinear orientation of grooves and total evacuation of air

To guarantee a full bed and eliminate the slightest air gap, the adhesive application movement obeys an absolute geometric rule: the grooves must imperatively be drawn straight, regular and strictly parallel to each other, oriented along the shortest side of the tile. This combing direction offers trapped air the shortest escape trajectory towards the outer edges during positioning. Any crossed application or circular movement traps closed air channels that can no longer evacuate, creating decompression chambers under the tile which dramatically reduce the adhesion surface.

  1. Unidirectional rectilinear combingApply adhesive to the substrate by drawing grooves parallel to the short side of the tile. Comb the back of the tile in the same parallel direction, never crossing the orientation of the teeth.
  2. Installation by perpendicular translationPresent the tile with a slight offset relative to its final position, then perform a back-and-forth lateral movement perpendicular to the axis of the grooves to break the mortar ridges.
  3. Mechanical beating or tappingBeat the surface from the centre to the periphery with a tiler's mallet or pass a vibrating float to drive residual air outwards and fuse the ribs into a homogeneous bed.

The conformity of adhesive transfer is systematically evaluated on the construction site by immediate destructive checks. The tiler must lift a freshly beaten tile at the beginning of each work shift to observe the back of the piece and the substrate. The contact surface must be full, without a distinct trace of residual groove or dry zone, achieving a continuous bed in accordance with the requirements of the SIA 248 standard. If trowel ridges remain visible after lifting, the tooth height, adhesive fluidity or beating energy must be readjusted before continuing installation.

Intervention procedure in case of incomplete transfer or flattening defect

Checking the installation bed is carried out from the very first tiles laid by lifting a control plate while still fresh. If the rear imprint reveals intact grooves, dry zones or a transfer rate below the requirements of the SIA 248 standard, installation must be interrupted immediately. The presence of air cavities under a large tile generally stems from an undersized notch, circular arc combing blocking air evacuation, or critical exceeding of open time. Letting a poorly filled tile harden inevitably leads to cracking under point loads and rapid debonding in the presence of underfloor heating.

  1. Removal and immediate cleaningRemove the incriminated tile before the adhesive mortar begins to set. Completely scrape off the fresh adhesive present on the masonry substrate and on the back of the piece using a steel spatula. It is strictly forbidden to compensate for a localized void with a punctual addition of paste, as this action generates thickness heterogeneities and differential drying shrinkage stresses.
  2. Adjustment of notch and rheologyCheck the mixing ratio and viscosity of the adhesive to ensure easy flattening without sagging. Replace the notched trowel with a half-moon profile model of larger radius or increase the pitch of the square notch. If the tile surface exceeds the standard template, switch without delay to systematic double gluing to saturate the back of the ceramic.
  3. Resumption of combing and beatingReapply the mortar in strictly rectilinear and parallel beads, oriented along the shortest side to minimise the air expulsion path. Place the element and execute energetic beating with the tiler's mallet or vibrating float, guiding the flattening from the centre to the edges to push all air pockets outwards.

Frequently asked questions

How to check the effective flattening of grooves during installation on a construction site?

From the very first sealed elements, lift a tile immediately after beating it. The reverse side of the tile must show continuous mortar impregnation, with no visible residual ridges. According to SIA 248, the contact rate must be total outdoors or on heated floors, and at least 90% in dry rooms. If hollows or unflattened grooves remain, adapt the trowel notch or adopt double gluing.

Why is the circular movement with the notched trowel prohibited during combing?

The arc movement generates adhesive ridges closed in on themselves. When beating the tile, the lateral rolls come into contact prematurely and trap air bubbles in the created cells, with no escape route towards the edges. By drawing grooves in strictly straight and parallel lines, the air evacuates continuously outwards under the pressure of beating, allowing total collapse of the beads and a full bed without residual voids.

What must be done on site if the adhesive mortar develops a surface skin?

When the adhesive begins to mattify and no longer sticks to the finger, its open time is exceeded. Attempting to lay the ceramic on this dry film prevents any transfer and guarantees future debonding. Never re-moisten the adhesive with a sponge or add fresh mix on top. The only professional method consists of entirely scraping off the weathered mortar down to the substrate, then reapplying a fresh layer with the appropriate trowel.

What final flattened adhesive thickness must remain under the tiles?

After methodical flattening of the grooves, the final thickness of the adhesive bed is generally between 2 and 4 millimetres depending on the relief of the reverse side and local flatness. A residual thickness of less than 2 millimetres no longer compensates for substrate tolerances and risks failure due to insufficient adhesion. Conversely, exceeding 5 millimetres causes excessive differential shrinkage during drying, leading to internal tensions and unevenness between adjacent slabs.

Texts and standards cited

  • SIA 248Tiled and panelled coverings

In the same section