Skip to content
Website
🧱 CFC 214Timber connections, ironmongery and fastenersChapter 10 of 10 in the section

Corrosion of fittings: when zinc-plated steel is no longer enough and stainless steel is required

After this chapter, you will be able to identify the aggressive environments that destroy the zinc layer on timber connections. You will choose between electrogalvanised steel, hot-dip galvanised steel or stainless steel depending on the actual exposure of the structure. You will master the prevention of galvanic coupling and the management of fittings that become invisible and inaccessible once wall linings are closed.

Key takeaways

  • Swimming pool chlorides and concentrated tannins rapidly destroy thin zinc coatings.
  • Electrogalvanised steel remains limited to heated indoor spaces in strictly dry environments.
  • Direct contact between stainless steel and galvanised steel creates a destructive electrochemical cell.
  • Any structural fitting rendered inaccessible by wall lining requires a maintenance-free, resistant alloy.

Identify aggressive atmospheres and select the correct surface treatment

On a timber framework construction site, specification errors regarding fittings often stem from an incorrect assessment of the indoor or outdoor environment. A structural metal connector must not be selected solely based on the tensile or shear loads it must withstand. Relative humidity, recurrent condensation, spray from a large lake, and the presence of volatile chemical agents directly determine the rate of degradation of the anti-corrosion protection. The exposure classes defined for the durability of connections require these aggressive factors to be assessed upstream of timber cutting and hardware ordering.

Behaviour of metallic coatings according to the surrounding environment
Type of fittingProtection thicknessPermissible applicationMain risk
Electrogalvanised steelApproximately 5 to 12 micronsHeated and dry indoor areas, enclosed structuresWhite rust then rapid loss of cross-section under moisture
Hot-dip galvanised steelApproximately 45 to 85 micronsOpen shelters, ventilated timber frameworks without chemicalsAttack by tannic acids or standing chlorides
A2 austenitic stainless steel (1.4301)Solid passivated alloyExposed outdoor areas, decking, watersideCrevice corrosion in confined chlorinated environments
A4 austenitic stainless steel (1.4401)Solid alloy with molybdenumSwimming pool halls, industry, moist acidic timbersHigher initial material cost

The atmosphere of an indoor swimming pool is the most destructive case for the carpenter. The combination of high temperature, permanent humidity, and volatile chlorine derivatives turns the zinc carbonate film into soluble salts. The protective layer of a galvanised joist hanger disappears in a few months, leaving the load-bearing steel to oxidise deeply. Similarly, beneath a ventilated roof in the mountains or along a lake, repeated nocturnal condensation on rafter feet or stirrups creates a continuously corrosive environment, exacerbated by the leaching of tannic timber species such as oak or sweet chestnut.

Master galvanic coupling and secure inaccessible connections

Introducing stainless steel fittings demands absolute rigour regarding the associated hardware. Creating direct physical contact between a stainless steel angle bracket and galvanised steel anchor nails or bolts generates severe galvanic coupling as soon as an electrolyte, such as condensation water, is present. The more electronegative metal—namely the zinc of the fastener—dissolves through sacrificial anode action. The fastener loses its effective cross-section or mechanical bond in a very short time, leading to the failure of the connection even though the main fitting remains intact.

  • Always combine stainless steel fittings with screws, ring shank nails or threaded rods of the same steel grade.
  • Insert washers or insulating shims made of neutral synthetic material if the separation of dissimilar metals is unavoidable.
  • Ban electrogalvanised steel for installing external timber frame hangers, even temporarily.
  • Record the compliance of each batch of screws used during assembly in self-inspection sheets.

The management of concealed structural connections represents the critical point for the contractor's liability. Under art. 365 CO, the contractor is liable for the satisfactory quality of the material supplied. In the case of an embedded connector box, a post base embedded in a screed, or a floor tie-rod concealed behind perimeter insulation, no visual inspection or re-treatment is conceivable during the life of the structure. If the zinc is destroyed by slow corrosion, the repair cost requires extensive demolition of linings and complex shoring of the timber framework.

Accelerated degradation under ventilated roofs and saturated atmospheres

On construction sites along French-speaking Swiss lakes or in structures housing indoor swimming pools, timber framework fittings undergo oxidation cycles that electrogalvanised steel cannot withstand. The air gap beneath a ventilated roof continuously draws in outdoor air laden with moisture and mineral aerosols. In the lake zones of Lake Geneva or Lake Neuchâtel, morning mist condenses directly on cold metal parts. Water stands through capillary action in contact with the load-bearing timber, progressively dissolving the zinc passivation layer without leaving the metal time to reform its protective carbonate.

The phenomenon becomes critical in the roofs of public or private swimming pools. Trichloramine vapours and volatile chlorides pass through vapour barriers via the slightest penetrations or travel through the internal volume. Under the combined effect of a temperature maintained above 28 degrees and constant relative humidity, the electroplated zinc disappears within a few months. The bare steel then suffers crevice corrosion that is invisible from the ground, accelerated by the acidic tannins of hardwood timbers or the moist resins of softwoods.

Fastener behaviour according to the operating atmosphere and steel type
Operating environmentElectrogalvanised steelHot-dip galvanised steelA2 stainless steel (1.4301)A4 stainless steel (1.4401)
Dry heated interior (service class 1)Compliant for visible partsOver-specified, raw appearance asideNot requiredNot required
Ventilated lakeside roof (service class 2)Prohibited (rapid pitting)Permitted if thickness is checkedRecommended for concealed fittingsRecommended on exposed verges
Aquatic hall / swimming pool (class C4 to C5)Proscribed (predictable failure)Proscribed (chlorinated acid attack)Not recommended (stress corrosion)Mandatory (or HCR grade)

Actual economic assessment and durability of non-inspectable fittings

The argument of the additional cost of stainless steel regularly blocks orders during the preparation of timber framework tenders. Yet, within the overall cost of a timber frame or a ventilated attic, structural hardware represents a tiny fraction of expenditure. Switching from zinc-plated steel screws to austenitic fasteners involves a real purchasing price difference on supply, but avoids disproportionate structural remedial work. Replacing a post base or a stirrup embedded in glulam requires full shoring of the bays, removal of linings, and hours of underpinning carpentry work.

The inaccessibility of fittings after installation dictates the required level of performance. As soon as a concealed web connector, threaded rod, or framework bolt is embedded in the thickness of thermal insulation, concealed beneath internal lining, or cast into a screed, no periodic visual inspection is feasible over the life of the structure. If the zinc fails, the shearing of dowels or failure of the fitting occurs without prior warning. Under art. 365 CO, the contractor is liable for the satisfactory quality of the material supplied; if any circumstance compromises the proper or timely execution of the work, the contractor must inform the client.

  • Systematically select grade A4 for all metal components located above chemically treated indoor water bodies.
  • Use polyamide or elastomer insulating washers to prevent direct contact between two metals with different potentials.
  • Ban the use of unregulated impact drivers that strip the protective surface treatment from screws during workshop tightening.
  • Document the technical data sheets of the installed stainless steels in the as-built documentation to prove compliance with SIA standard requirements.

Managing non-conformities and repairing corroded connections

The discovery of rust on a structural fitting during construction site work or during an inspection requires an immediate stop to the initial design assumptions. When standard zinc-plated steel has been installed by mistake in a damp or chlorinated environment, material loss on rods or steel webs compromises the load-bearing capacity of the timber connection. The site foreman must cordon off the area and carry out an accurate visual survey of the damage.

  1. Non-destructive testing and diagnosisCheck the depth of oxidation on visible parts using a vernier caliper and inspect fissures in solid or glulam timber. If corrosion affects an inaccessible fitting or one embedded in a rebate, remove a sample component to evaluate the attack within the core of the timber, which is often accelerated by tannins or residual moisture.
  2. Contractual notification and notice of defectsNotify the site management in writing without delay. In accordance with art. 365 CO, if a prescribed or supplied material compromises proper execution, the contractor must inform the client. For works that have already been handed over, reporting falls within the scope of CO relating to the examination and notification of defects.
  3. Temporary shoring and load transferInstall heavy-duty shoring to relieve the weakened connection before any mechanical intervention. The jacking system must take up all permanent loads to allow the removal of fasteners without movement of the load-bearing structure.
  4. Complete replacement with stainless steelReplace all joist hangers, dowels, bolts, and washers with A2 or A4 stainless steel components depending on the observed environment. Prohibit any mixing of metals: fasteners must imperatively exhibit a corrosion resistance class identical to that of the internal steel plates.

Frequently asked questions

Can a galvanised steel joist hanger be fixed using A2 stainless steel screws?

No, this combination creates destructive galvanic coupling in a damp environment. The zinc of the fitting, being the less noble metal, acts as a sacrificial anode and degrades rapidly around the stainless steel screw head. To prevent any electrochemical cell and guarantee the transmission of static forces, the fitting, dowels, and anchor nails must imperatively be made of the same metal or insulated with dielectric shims.

Why does the exposure class require stainless steel under a ventilated lakeside roof?

Outdoor air along lake shores carries high relative humidity combined with aggressive particles. Beneath the roof covering, the ventilation air gap operates continuously and produces repeated condensation cycles on the cold metal. Electrogalvanised steel loses its thin protective film within a few seasons. Stainless steel guarantees a fifty-year service life that is indispensable for these framework components, which become permanently inaccessible after battens are fitted.

Which grade of stainless steel should be selected for the timber framework of an aquatic centre?

Indoor swimming pools feature a chloramine-saturated atmosphere that is particularly aggressive, causing stress corrosion cracking in common steels. Standard A2 or even A4 stainless steel proves insufficient for parts under high mechanical tension located above swimming pools. The timber engineer must imperatively specify special austenitic stainless steels with high molybdenum content or duplex grades, suited to extreme and unventilated corrosive environments.

How should a concealed web fitting in tannin-rich timber be treated?

Species such as oak or sweet chestnut release tannic acids in the presence of moisture exceeding 18%. These substances severely attack the zinc on internal plates that are confined and deprived of oxygen to reform their protective patina. In these enclosed configurations where no subsequent visual inspection is possible, using A4 stainless steel fittings and dowels constitutes the only guarantee against premature structural failure.

Texts and standards cited

  • CO art. 365materials and site conditions: the contractor informs the client immediately if any circumstance compromises proper execution
  • COexamination of the work and notification of defects to the contractor