Skip to content
Website
🧱 CFC 283Parquet sanding: grits and flatnessChapter 5 of 10 in the section

Filling: wood-dust paste, joints that are too wide and mastic extrusion

This chapter guides you through preparing a homogeneous wood paste from your sanding dust and defines the strict limits for filling gaps. You will learn to identify mechanical defects linked to ambient humidity, select permissible gaps, and leave gaps subject to dimensional variations open to ensure finish durability.

Key takeaways

  • Filling paste must be prepared exclusively using clean dust from intermediate-grit sanding.
  • Standard SIA 253 governs substrate condition and tolerates the natural movement of boards.
  • Gaps exceeding two millimetres inevitably push out filler resins during the first winter cycle.
  • The parquet layer keeps perimeter joints and structural separations prone to shrinkage open.

Prepare the wood paste and apply the binder according to the rules of the trade

Full or localized filling aims to fill micro-cracks, torn fibres, and capillary gaps before applying primers or sealing coats. According to the specifications of standard SIA 253, the wooden floor must present a continuous and clean surface, without freezing the overall movements of the flooring. To obtain a shade that perfectly matches the work, the parquet layer manufactures their own paste by combining a specific binding resin with sanding flour taken directly from the construction site.

  1. Collection of raw materialIsolate the fine dust from the eighty or one hundred grit abrasive pass. Empty the bag of the belt sander or edge sander beforehand to guarantee the absence of smoothing compound dust or foreign wood species.
  2. Mixing the binderMix the wood flour with the fluid binder in a clean bucket until a creamy and supple consistency is obtained, similar to a lightened glazier's putty. Excess flour makes the product friable and accelerates its premature drying, while a lack of dust leads to hollow shrinkage after evaporation of solvents or water.
  3. Spatula fillingWork the mixture in using crossed passes with a wide, flexible stainless-steel spatula. Manual pressure must force the paste to the bottom of the cavities while scraping off the excess on the surface to facilitate subsequent finishing sanding.

The drying time of the paste varies depending on the nature of the binder used. Solvent-based binders dry quickly and allow work to resume after about thirty minutes, but they require enhanced room ventilation and the wearing of respiratory protection. Aqueous-phase resins require one to two hours of evaporation and minimize odour emissions, although they are more sensitive to cool temperatures below fifteen degrees.

Understand seasonal work to distinguish permissible gaps

Wood is a hygroscopic material whose dimensions constantly vary throughout the seasons. In Western Switzerland, the winter period corresponds to the activation of heating systems, causing a significant drop in indoor relative humidity, which often falls below the forty percent mark. Parquet boards release their equilibrium moisture, shrink, and open up gaps between edges. Conversely, summer brings warm, humid air that expands the parquet until the joints close completely.

Diagnosis and treatment of parquet gaps before finishing
Joint widthMechanical behaviourTechnical specificationConsequence if filled
Less than 1 mmLow capillary movementsFull fluid filling permittedDurable hold without cracking
1 to 2 mmModerate tension and pushLocalized filling in repeated passesRisk of sagging or slight crack
Greater than 2 mmStrong dimensional variationInstallation of a glued sliver or leaving openComplete ejection of the cord in winter
Perimeter or movement jointTotal freedom required by the standardLeave free under skirting or profileUplifting of entire bays

When facing an old or nailed floor showing recurring gaps of more than two millimetres, the parquet layer must strictly refrain from blind filling. These spacings act as the lungs of the parquet: filling them condemns the work to aesthetic defects and squeaking when moisture returns. If the presence of large gaps shocks the client, the sustainable technical solution consists of inserting solid wood tongues cut from the same wood species, called slivers, glued on only one side so as not to restrict the natural movement of the wood.

Permissible width and extrusion mechanism of wood paste

Full-surface filling on an existing or freshly laid parquet complies with strict building physics rules. In Western Switzerland, the alternation between humid summers and winters marked by intensive heating induces variations in ambient relative humidity frequently oscillating between 30% and 70%. Wood reacts according to its fibre saturation point with permanent tangential and radial shrinkage. Standard SIA 253 governs requirements relating to wooden floor coverings and implicitly reminds us that the material remains alive after installation. Filling a gap never cancels out the dimensional movement of the boards.

Paste made on site with solvent-based or aqueous-phase binder and 80 to 100 grit flour has only minimal residual elasticity. As soon as the width of the void exceeds 2 mm, or as soon as the board exhibits transverse translation freedom, the mechanical stress exceeds the internal cohesion of the mixture. During the winter heating period, the air dries out, the boards shrink, and the joint opens further. The mastic bead undergoes direct transverse tension: it breaks at the core or loses its adhesion on one of the flanks of the board.

The parquet layer must imperatively evaluate the stability of the floor before undertaking generalized filling with a spatula. A parquet nailed onto old joists, featuring a ventilated underside or laid on a flexible subfloor, undergoes vertical flexions under foot traffic. These differential vertical movements instantly break the bond between the binder and the board cheeks. Filling must under no circumstances serve as an expedient to mask structural play or compensate for mechanical unevenness.

On-site arbitration: areas to fill, gaps to respect, and sliver insertion

Visual and hygrometric diagnosis guides the application of loaded binder. Straight gaps distributed homogeneously across the room reflect the normal breathing cycle of the work. Wanting to freeze these breathing movements under a bed of agglomerated dust constitutes a definite technical defect. The parquet layer accepts the presence of certain gaps or resorts to a traditional woodworking method when the width compromises the durability of the floor.

Decision matrix for treating defects and joints before finishing
Observed configurationSizingMechanical behaviourTechnical specification
Grain micro-cracks or splitsLess than 1 mmStatic, internal to the boardFull filling with stainless-steel spatula before final sanding
End joints at board endsUp to 1.5 mmVery low axial movementPressure filling with spatula, fluid paste
Longitudinal assembly joints1 to 2 mmRegular seasonal movementFilling tolerated only on stable fully-bonded parquet
Longitudinal wear gaps2 to 6 mmHigh amplitude, nailed parquetLeave open or install a sliver glued on a single edge
Perimeter and expansion playsGreater than 8 mmOverall panel variationNever fill: mask with skirting or counter-profile

When the parquet presents open gaps exceeding 2 to 3 mm on historic solid boards, the only response in accordance with the rules of the art lies in sliver insertion. The sliver consists of a solid wood strip machined from the same species, cut flat-sawn or quarter-sawn to match the surrounding grain, and fitted with a router or plane into the cleaned gap. This intermediate piece is glued on one side only so as not to block the natural sliding of the parquet during humid seasons, then planed down before equalisation sanding.

In summary, paste formulated with sanding dust is used to perfect the surface finish, fill torn fibres, plug small nail holes, and stabilize motionless board ends. Any joint that opens and closes at the mercy of the thermohygrometer must be left free to evolve, thereby preserving the integrity of the seal or oil impregnation.

Managing defects: reworking expelled mastics and site arbitration

When winter shrinkage compresses or stretches the edges, loss of mastic adhesion is inevitable on active gaps. The binder mixed with wood flour, rigid once dry, fractures into small detached rolls or crumbles under vacuuming. As soon as expelled ridges or powdery hollows appear after the first heating period, the craftsperson must intervene methodically without trying to reinject identical paste into an unstable void.

  1. Mechanically purge defective cordsClear out the old dry mastic using a triangular parquet scraper or a fine gouge, without damaging the sharp edges of the oak or softwood boards. The use of a rotary router mounted on a guide remains reserved for straight, continuous gaps.
  2. Vacuum groove bottomsEvacuate all residual dust and friable debris right to the bottom of the rebate using an industrial vacuum cleaner equipped with a narrow crevice nozzle to guarantee perfect visibility of the joint bottom.
  3. Arbitrate between open joint and sliver insertionMeasure the actual gap of the cleaned void. If the opening exceeds two millimetres, insert a custom-cut straight-grained wood tongue in the same species, glued exclusively to a single flank. For smaller gaps, keep the joint open to preserve the free movement of the boards.
  4. Touch up surface protectionLevel the flush plane with a miniature plane or by manual fine-grit light sanding, then reapply the wax oil or sealer compatible with the existing system locally, without creating peripheral gloss.

The management of these defects requires clarification with site management: seasonal dimensional movements remain intrinsic to the material according to standard SIA 253. Attempting to seal dynamic joints beyond the physical tolerances of the wood compromises the durability of the work without offering long-term aesthetic guarantees.

Frequently asked questions

What to do if the paste made with the dust darkens excessively upon drying?

Flour from fine 80 or 100 grit sanding reacts with the binder solvents, accentuating the tannins in the oak. To correct a shade that is too dark before global application, always make a test mix on an offcut. If the shade turns greyish, substitute part of the flour with clean sawdust from unburnt workshop cuts.

Why is full filling of an old parquet on joists prohibited?

Old nailed solid parquets exhibit mechanical flexibility under footsteps and very high hygrothermal amplitude. A rigid resin-and-dust mastic supports neither the micro-flexion of the boards nor the seasonal play of the joists. The cord breaks up within a few weeks, producing abrasive dust under the occupants' footsteps.

From what width should a parquet joint no longer be filled?

Beyond two millimetres of clear void, the paste volume undergoes excessive volumetric shrinkage during solvent evaporation, generating immediate hollows. Furthermore, the resin mass becomes too rigid in the face of transverse dimensional variations. These large gaps strictly require sliver insertion using a wood fillet adjusted and glued unilaterally.

How to explain the presence of visible micro-gaps in the middle of winter to the client?

Solid wood is a hygroscopic material that equilibrates with ambient air. During the heating period, the relative humidity in rooms often drops below 35%, causing natural fibre shrinkage. According to standard SIA 253, the appearance of fine seasonal gaps is a normal and temporary physical behaviour, which resolves naturally when summer humidity levels rise.

Texts and standards cited

  • norme SIA 253Installation and requirements relating to bonded floor coverings and parquet

In the same section