Key takeaways
- Full-scale ground setting out ensures accurate radii and precise cutting of ribs.
- Plywood thickness and grain direction dictate the allowable limit radius without fibre failure.
- Stiffening with curved walers and tie rods resists the hydrostatic pressures of fresh concrete.
- Custom form pieces require strict opening control to prevent creep under load.
Full-scale setting out, templates, and bending of formwork skins
Industrial formwork panels reach their limits as soon as the project dictates a radius tighter than the capacity of adjustable curved panels, a variable curvature (basket-handle arch, clothoid), or a complex angular junction. For these non-standard geometries, traditional timber formwork comes into its own. Work begins with a full-scale layout struck directly onto a chipboard platform or onto the raft slab. Using a steel chalk line, a straight edge, and a marking gauge, the neutral axis and both faces of the wall are marked out. This layout is used to fabricate templates from 21 or 27 millimetre wood-based panels, which will then guide the cutting of horizontal ribs or load-bearing curved frames.
- Curved frame
- Timber framework cut to the theoretical radius of curvature, assembled by flitch plating or nailing, serving as direct support for battens or thin formwork panels.
The selection of the formwork skin depends directly on the minimum radius of curvature specified in the formwork drawings. Standard 15-millimetre birch plywood cannot be bent below a radius of 2.5 to 3 metres without suffering delamination or surface cracking. For sharper curves, using thinner panels (6, 8, or 9 millimetre panels laid in cross-laminated layers) becomes essential. The grain direction of the panel also governs its flexibility: bending plywood parallel to the grain of its face veneers requires less effort but exposes the surfaces to blistering during vibration.
| Nominal thickness | Bending direction | Indicative minimum radius | Typical use |
|---|---|---|---|
| 6 mm | Perpendicular to grain | 0.80 m to 1.00 m | Double layered skins for tight columns |
| 9 mm | Perpendicular to grain | 1.40 m to 1.60 m | Curved walls for spiral staircases |
| 15 mm | Perpendicular to grain | 2.80 m to 3.20 m | Large-radius curved retaining walls |
| 21 mm | Perpendicular to grain | 5.00 m and above | Large basins and car park ramps |
For radii under 80 centimetres, planed softwood matchboarding with chamfered tongue and groove replaces flat sheeting, unless the plywood is steam-bent using hot water. Mechanically fixing the skin onto the ribs must proceed from the centre of the template towards the ends to eliminate crowning and residual tension in the timber.
Stiffening, load transfer, and dimensional control of custom form pieces
The kinematics of forces in curved formwork differ fundamentally from those in straight panel formwork. Liquid concrete pressure generates tangential thrusts that tend to burst the arch open or displace the centreline. The primary framework cannot rely on standard straight steel sections without adaptation: curved ribs cut from glued-laminated timber or heavy-section planks (75 x 150 millimetres minimum) receive vertical stiffeners spaced according to the planned rate of placing.
- Setting out and wedging the bottom ribFix the curved sole plates to the ground with hammer-set anchor plugs following the layout, then position kickers to prevent any lateral sliding.
- Assembling the frame cageErect the vertical frames and tie the curved walers together at regular intervals, typically spaced closer together over the first metre of height.
- Drilling and fitting tie rodsDrill through the skin perpendicular to the tangent of the curve to prevent articulated wing nuts and bearing plates from bending under biaxial loads.
- Bracing and triangulationInstall push-pull props directed towards the centres of the radius and diagonally brace the structure to prevent racking under asymmetrical pressure.
Reusing these bespoke structures remains very limited. Subject to permanent deformation caused by lateral pressure and concrete moisture cycles, the timber works: the framework frames suffer creep and the thin skins absorb mix water, making a second pour dimensionally risky without re-truing. A complex element allows for only two to three pour phases at most before complete refurbishment of the contact skin.
Erecting such a structure requires constant vigilance regarding assembly safety. The employer applies art. 3 OPA to provide working installations that ensure personnel protection, notably adapting suspended pouring platforms to non-linear geometries. Furthermore, in accordance with art. 77 OTConst, falsework and supporting structures must be dimensioned to withstand the foreseeable loads and forces on the construction site.
Tolerance control and stabilization of custom form pieces
Constructing reinforced concrete elements with complex geometry, such as curved walls or polygonal drop beams, requires assembly precision that hand-set modular systems cannot achieve. While standardized metal panels impose a rigid tie grid, traditional timber construction places all stiffness on the formwork carpentry: glued flitch plates, template-cut frames, and distribution walers. The slightest inaccuracy in cutting flitches or inadequate wedging of tie rods leads to displacement under the hydrostatic pressure of fresh concrete, irreversibly distorting the intended curvature.
To meet execution dimensions, allowable deflection of the formwork skin between vertical stiffeners (studs or secondary beams) is restrained by reduced spacing. Unlike straight walls where stiffener centres commonly reach 30 to 50 cm, a curved surface with a tight radius often requires a spacing of 15 to 20 cm to prevent faceting of thin plywood. Fixing anchor ties cannot be done perpendicular to an ordinary flat face: it requires bevelled hardwood wedges or suitable swivel plates, otherwise the rods may be subjected to shear or the backing ribs may experience localized crush failure.
During alignment on the sole plate, lateral thrust forces are resisted via push-pull props anchored to the ground or to a concrete kicker. Art. 77 OTConst requires falsework and sheeting to withstand foreseeable loads and forces, be built to recognized technical rules, and be dimensioned taking additional loads into account. On single-sided curved formwork, uplift force at the foot and overturning must be resisted by steel walers tied to the timber frames to prevent any lifting as the concrete rises.
Material wear, limited reuse, and end-of-phase recovery
Traditional timber formwork for complex shapes offers significantly lower durability than industrial metal systems. Mechanical stresses exerted on thin skins during bending create micro-cracks in the outer veneers of the plywood. These tears promote the absorption of water and cement paste, causing localized wood swelling, edge delamination, and loss of tightness at joint lines.
| Formwork component | Structural role | Average number of reuses | Limiting factor for durability |
|---|---|---|---|
| 6-9 mm bendable plywood | Formwork face in contact with concrete | 1 to 2 times | Veneer cracking, blistering under moisture, tearing on stripping |
| Bevel-cut 21-27 mm 3-ply panels | Curved frames and shaped ribs | 3 to 5 times | Permanent deformation, splitting around repeated screw zones |
| Glued-laminated walers and stiffeners | Framework resisting anchor tie loads | 6 to 10 times | Punching failure from bearing plates, hole ovalisation |
| Close-jointed trapezoidal fir battens | Soffits or drop beams with very tight radius | 1 single use | Impregnation with cement paste, inability to re-profile |
Each striking operation demands special precautions to protect the ribs. Using stripping levers or crowbars directly against curved edges destroys machined profiles. Pressure relief panels and release wedges should be incorporated into the design of the timber structure from the start. As soon as geometric tolerances are no longer guaranteed or edges exhibit spalls exceeding 2 mm, components must be downgraded to non-exposed areas or scrapped.
Art. 365 CO reiterates the contractor's liability for the good quality of materials supplied. On a curved structure requiring a high-quality finish, using timber that has already undergone plastic deformation exposes the contractor to rejection of the works for non-compliance with execution geometries. Factoring depreciation costs into a very short reuse cycle is thus the linchpin of profitability for custom-shaped formwork.
Managing dimensional deviations and failures in curved formwork
On curved structures and non-standard custom shapes, the slightest lack of stiffness translates into visible deformation under the pressure of fresh concrete. When a rib fails, a template deflects, or grout leaks at the joint between curved panels, action must be immediate to stop pouring before setting occurs and prevent the structure from drifting out of tolerance.
- Halting the pour and emergency stabilizationHalt the skip or concrete pump as soon as abnormal deflection is observed. Measure the warp using a checking template or a plumb line. If the stiffening is bursting open, install inclined emergency rakers anchored to the slab below or strap the formwork box with temporary threaded through-ties.
- Cleaning out and re-setting the layoutIf the deformation exceeds permissible execution tolerances, remove the unhardened fresh concrete by hydrodemolition or manual scraping before it sets. Strip the damaged plywood skin, rebuild the skeleton of curved ribs on the ground layout, and replace any split stiffeners.
- Formal notification to site managementNotify without delay of any observed geometric defect or inability to meet the engineer's drawing dimensions due to reinforcement clashes. Art. 365 CO al. 3 requires the contractor to inform the employer if any circumstance compromises the proper or timely execution of the works.
If geometric damage is found after striking, the site foreman records the actual dimensions using a topographical survey. No thick patching mortars or structural scabbing may be undertaken without the written approval of the civil engineer responsible for the structural design of the civil engineering work or building.
Frequently asked questions
How can out-of-round defects on a curved wall be corrected after striking?
If the actual radius deviates from the layout beyond contractual tolerances, the civil engineer must evaluate the impact on reinforcement cover and structural capacity. In the event of excess thickness, mechanical planing or bush hammering may be permitted. For hollow areas, applying a structural repair mortar requires surface preparation by grit blasting and the prior approval of site management.
What should be done if thin plywood snaps during bending over a template?
Breakage indicates a radius of curvature that is too tight for the chosen thickness or an unsuitable grain direction. Switch to a thinner multi-ply panel installed in two cross-laminated layers, for example two 8 mm sheets instead of one 15 mm sheet. Controlled wetting of the outer face during bending also softens the wood fibres before mechanical fastening to the walers.
How should a form joint bursting open between curved panels during pouring be dealt with?
Pouring must be stopped immediately to reduce the hydrostatic head. Fit a rigid cover strip from the outside, nailed or screwed to the stiffeners, and seal the opening with fast-setting expanding foam or a compatible sealant. Then reduce the rate of concrete rise to limit lateral pressure on the weakened area when resuming the pour.
Can bespoke timber formwork deformed during a first pour cycle be reused?
Reusing a curved custom form piece requires a full check of the load-bearing skeleton against the ground layout. If the timber ribs have acquired residual deflection under load or swelling from moisture, they must be trued up or doubled. Damaged or delaminated formwork skin must be systematically replaced to ensure tightness and accurate geometry for the second phase.
Texts and standards cited
- COmaterials and ground: the contractor is liable for the good quality of materials supplied; if materials supplied by the employer or the ground designated by the employer are found to be defective, or if any other circumstance compromises the proper or timely execution of the works, the contractor must immediately notify the employer, or bear the consequences (al. 3)
- OTConstprotection against the collapse of building elements or falling objects and materials: at workstations and access routes, measures must be taken to ensure workers are not endangered