Skip to content
Website
🧱 CFC 211.1Section 3 of 610 chapters

Slabs, floors and floor plates: execution reference framework

Intended for team leaders, site foremen and structural work site managers, this section details the execution of floors and floor plates according to standards SIA 262 and SIA 260. It guides the assembly of propping, punching shear transfer, deflection management and structural connections, ensuring team safety and structural stability.

  • 10chapters
  • 22 000words
  • 6sections in the training course
  • 60chapters in total

Key values to remember 4

OTConst art. 23

2 m

Fall height requiring edge edge protection guardrails along slab edges

OTConst art. 22

100 cm

Minimum height of the top guardrail above the walking surface

OTConst art. 22

47 cm

Maximum vertical clear distance between horizontal guardrail rails

OTConst art. 22

15 cm

Minimum height of the toeboard fixed along the floor edge

Technical scope and trade boundaries

The construction of floors and slabs forms the primary horizontal framework of a reinforced concrete building according to standard SIA 260. This technical dossier deals exclusively with mechanical behaviour, formwork, reinforcement and structural assembly of horizontal elements. It covers in-situ solid slabs, job-site or precast floor plates with their top concrete topping, ribbed floors as well as complex cantilevers subjected to severe thermal and static stresses.

The site foreman must maintain strict vigilance over the transfer of forces during concreting. The installation of precast elements requires millimetric verification of bearing surfaces and precise marking of propping lines. Any deviation from formwork and reinforcement drawings directly compromises the compliance of the finished structure with serviceability limit states and ultimate limit states.

Methodical floor execution workflow

To organise slab works without risking structural defects, reviewing execution documents must follow the chronological order of site loads. Installation starts with bearing the precast units and their temporary support, continues with connection reinforcement, and finishes with strict monitoring of striking and temporary loads.

  1. Installation and continuity of floor platesModules A3-01 and A3-02 detail the adjustment of falsework ledgers, minimum bearing depths on walls, and the installation of shear reinforcement to ensure composite slab monolithism.
  2. In-situ pouring and lightweight floorsGuides A3-03 and A3-04 cover mid-span reinforcement of solid slabs, adherence to span directions, and the execution of hollow-block floors to limit structural dead load.
  3. Critical zones and deformationsChapters A3-05 and A3-06 address the risk of punching failure at columns using links or shear stud rails, as well as formwork camber adjustments required by standard SIA 262.
  4. Geometric specifics and surface finishesFactsheets A3-07 to A3-10 analyse opening trimming reinforcement, installation of balcony thermal break cages, power floating, and strict curing times prior to pallet storage on young slabs.

📘 Chapters in this section 10

Slabs, floors and precast half-slabs

Laying precast floor slabs: bearing length, temporary propping and laying sequence

Ensure stability during lifting and comply with the minimum bearing depth required on your supports.

Slabs, floors and precast half-slabs

Grouting of floor plates: tie reinforcement and continuity between panels

Achieve structural monolithism of your floor using code-compliant shear reinforcement.

Slabs, floors and precast half-slabs

In-situ cast solid slab: thickness, span and span direction

Optimise formwork depths and master the exact orientation of main load-bearing spans.

Slabs, floors and precast half-slabs

Beam and block floor: centre-to-centre spacing, propping and compression slab

Reduce dead loads while securing centre-to-centre spacing and slab pouring.

Slabs, floors and precast half-slabs

Punching shear in a slab on column: identify and correctly install specific reinforcement

Eliminate the risk of brittle shear failure around columns using engineered reinforcement.

Slabs, floors and precast half-slabs

Slab deflection: precamber during execution and measurement after striking formwork

Anticipate deflection under load and adjust your formwork to the required tolerances.

Slabs, floors and precast half-slabs

Stair and lift openings: trimmers, edge reinforcement and tolerances

Secure stair and lift openings using strictly reinforced trimmers.

Slabs, floors and precast half-slabs

Cantilever balcony: structural thermal break, installation orientation, and top reinforcement mesh

Prevent any thermal or structural defect by precisely aligning your balcony thermal breaks.

Slabs, floors and precast half-slabs

Slab surfacing: power floating, trowelling and finish level to declare

Attain expected flatness through power floating tailored to the target finish class.

Slabs, floors and precast half-slabs

Loading green slabs: material storage and critical limits

Prevent early cracking by planning temporary storage loads on green concrete.