Skip to content
Website
🧱 CFC 271Surface quality levels and tolerancesChapter 2 of 10 in the section

Measuring flatness: two-metre straightedge, gauge wedge and tolerance by grade

This chapter details the contractual method for measuring the flatness of a plasterboard lining or an interior render in accordance with SIA 242. You will learn how to handle the two-metre straightedge and the graduated measuring wedge, how to apply the geometric tolerances specific to each quality grade, and how to distribute your check points so as to secure a joint acceptance inspection.

Key takeaways

  • The geometric check is carried out exclusively with a rigid straightedge and a graduated wedge, never by eye.
  • Raking light is not a measuring instrument for the tolerances defined by the standards.
  • SIA 242 sets the permissible deviations under the straightedge according to the finish grade selected.
  • The protocol requires at least three crossed measurements per wall section for a representative sample.

The inspection protocol: two-metre straightedge and measuring wedge versus visual arbitrariness

On a plastering or drylining construction site, surface disputes often arise from a raking spotlight or a subjective visual assessment. Yet, contractually and technically, visual appearance never replaces geometric verification. The conformity of a plasterboard lining or an interior render is assessed by comparing the actual deviations with the limit values set by SIA 242. To qualify a surface, the installation team or the site management must abandon assessment by eye and apply a reproducible physical method. Physical measurement requires standardised equipment: a two-metre aluminium inspection straightedge, free of distortion, and a bevelled measuring wedge graduated to the half-millimetre.

  1. Checking the straightness of the straightedgeBefore each inspection campaign, the condition of the two-metre straightedge is checked on a flat reference surface. A straightedge with a hollow greater than half a millimetre or with burrs distorts all the readings on the construction site.
  2. Placing the straightedge without applying pressureThe two-metre straightedge is placed gently on the lining, without pressing, so as not to compress the board or flex the aluminium. Hold the straightedge steady, perpendicular to the plane or along the diagonal being checked.
  3. Inserting the measuring wedge under the deflectionThe technician locates the maximum hollow under the sole of the straightedge. The bevelled measuring wedge is then slid into that spot, perpendicular to the straightedge, without forcing. Gentle contact indicates the exact height of the gap.
  4. Reading the value without damaging the substrateThe millimetre value is read on the wedge graduation, in line with the lower edge of the straightedge. Do not insert the wedge at an angle or score the render with the metal tip, as this would distort the measurement.

When the defect appears as an isolated bump, the straightedge rocks around a central point of support. The protocol then consists of wedging one end of the straightedge against the wall, then sliding the measuring wedge under the opposite end. The distance measured between the sole and the wall quantifies the amplitude of the bump relative to the two-metre reference chord.

Permitted tolerances by quality grade and the sampling method

SIA 242 governs plastering and suspended ceiling work. The deviation tolerances under the two-metre straightedge depend directly on the surface quality grade defined in the contract documents. Grade Q1 has no fine flatness requirement, as it applies to technical surfaces or surfaces intended to receive thick tiling. The standard grade Q2 corresponds to ordinary partitions receiving matt or coarse-grain wall coverings. Grades Q3 and Q4 impose stricter straightness, suited to smooth finishes, lacquers or satin paints.

Flatness tolerances under a 2 m straightedge according to SIA 242
Quality gradeTolerance under 2 m straightedgeTypical application
Q1Not specifiedPlant rooms, tile substrate
Q25 mmStandard finish, matt paints
Q33 mmIncreased requirements, thin coverings
Q42 mmHigh-quality requirements, smooth surfaces

To avoid disputes over an isolated point, the standard recommends a methodical distribution of checks. An acceptance is never based on a single measurement. On each wall section of at least ten square metres, the team applies the straightedge at five distinct points: two horizontal measurements at different heights, two vertical measurements, and one diagonal measurement crossing the board joints.

During acceptance operations, the traceability of the checks protects the parties. Art. 367 CO provides that the client inspects the condition of the work and notifies the contractor of defects. Drawing up joint minutes, recording the location of the readings, the contractual grade and the values read with the measuring wedge, prevents any later dispute before the painter starts work.

Carrying out the joint measurement: positioning and reading the deflection

On a plastering and drylining construction site, a subjective assessment of a surface has no legal or technical value. Disputes based on a distracted glance or on the harsh light of a floor spotlight do not constitute an admissible finding. The flatness of a plasterboard lining or an interior skim render is checked exclusively with calibrated measuring instruments: the rigid two-metre straightedge and the graduated bevelled measuring wedge. This metric protocol records the real deviation between the theoretical straight line and the surface actually produced by the drylining contractor.

  1. Checking the straightness of the reference toolBefore any joint reading on the partition or suspended ceiling, the edge of the two-metre straightedge must itself be free of warping, knocks or dried plaster deposits. Two aluminium straightedges placed edge to edge against a light source must show no gap greater than half a millimetre along their entire length.
  2. Free positioning on the test surfaceThe two-metre straightedge is laid on the lining without applying any mechanical stress or manual pressure at the centre, which would distort the measurement through elastic deformation of the board or the tool. It rests naturally on the two highest points of the bay under examination.
  3. Inserting the graduated bevelled wedgeInto the hollow between the edge of the straightedge and the visible face of the work, the technician slides a metal measuring wedge graduated in millimetres, perpendicular to the straightedge. The wedge enters without forcing until it meets resistance. The figure read at the lower edge of the straightedge gives the actual deflection.
  4. Checking bumps and high pointsWhen the straightedge pivots around a central bump, it rocks. The measurement then consists of firmly wedging one end against the lining and measuring the maximum overhang at the other end with the graduated wedge, the total value being halved to qualify the actual projection.

SIA 242 flatness tolerances and the grid of check points

SIA 242 defines strict dimensional tolerance criteria for plastering, interior rendering and drylining work. The permissible deviation under the two-metre straightedge varies according to the surface quality grade stipulated in the works contract. A metric result cannot be interpreted without knowing the agreed level of requirement: a deviation of four millimetres is perfectly acceptable for a standard Q2 finish, whereas it leads to rejection for a Q4 lining intended to receive a gloss lacquer.

Flatness limit values under a 2 m straightedge by SIA 242 quality grade
Quality gradeStandard designationMaximum deviation under 2 m straightedgeTypical field of application
Q1Basic requirements≤ 8 mmSurfaces with no decorative function, technical linings behind closed ducts
Q2Normal requirements≤ 5 mmDefault standard: textured wall coverings, thick wallpapers
Q3Special requirements≤ 4 mmFine matt paints, thin wallpapers, carefully designed lighting
Q4Higher requirements≤ 3 mmSatin or gloss paints, smooth stucco, direct raking light

The validity of an inspection rests on a representative sample and a methodical distribution of check points. The aim is not to look for the single worst point, but to qualify the general quality of the wall section or ceiling surface. Measurements must be distributed evenly over the whole area being accepted, avoiding an arbitrary concentration on board junctions alone.

  • Minimum measurement density: at least three separate readings for a partition section under twenty square metres, then one additional measurement for each additional ten square metres or part thereof.
  • Alternating tool orientation: place the two-metre straightedge vertically, horizontally and then on both diagonals to pick up both framing deflections and render misalignments.
  • Systematic checking across joints: at least half of the readings must straddle the transverse or longitudinal joint tapes to verify the continuity of the plane.
  • Clearance from edges: the straightedge must not be positioned within ten centimetres of internal or external corners, to avoid mechanical disturbance from reinforced corners.
  • Ceiling readings: regular grid at the centre of the suspension profile bays and across the recessed lighting lines.

Each measurement taken is immediately recorded, with the deflection found, on a marking-out plan or in the joint minutes. When a measurement exceeds the tolerance prescribed by SIA 242 for the agreed grade, the team leader or site manager has the area locally reworked by mechanical sanding of the render or by reapplying a filler coat before any final presentation to the site management.

Handling disputes and rectification protocols in case of exceedance

On site, disputes almost always arise when the site management or the painter judges a lining by the naked eye or under a raking site spotlight. Faced with this kind of subjective criticism, the team leader must immediately bring the discussion back to the technical ground: only physical measurement with the rigid two-metre aluminium straightedge and the graduated bevelled wedge is authoritative under SIA 242. A visual inspection never constitutes an admissible finding of a flatness defect.

  1. Demanding the standardised joint checkReject any remark not recorded on the basis of a regular sampling survey. Place the two-metre straightedge on the disputed area, slide the measuring wedge without forcing at the point of maximum deflection and record the exact millimetre value in the presence of the client's representative.
  2. Checking the geometric origin of the defectDistinguish render thickness from the deformation of the framing or of the raw substrate itself. If the measured deflection exceeds the agreed tolerance but results from an out-of-plumb or a bulge in the load-bearing structure upstream, the plasterer records this finding to clear his execution liability.
  3. Recording the rectification methodWhen the deviation exceeds the contractual tolerance because of the plasterer, the rectification must remain targeted. On a drylined partition, a local bump calls for mechanical sanding of the joint or local cutting back followed by new filling. A hollow is made good by feathered rendering extending at least 30 centimetres on either side.

If disagreement persists after the joint measurement, have the raw values entered in the site minutes. In case of proven non-conformity attributable to the plastering team, propose a written rectification protocol before any intervention by the painter, because applying the primer coat definitively fixes responsibilities and makes later sanding more costly.

Frequently asked questions

Can the site management reject a drylined partition by holding a torch against the surface?

No. SIA 242 formally excludes inspection under raking light to accept or reject a standard quality grade. The conformity check is carried out exclusively under diffuse lighting representative of the normal conditions of use of the room, supplemented by instrumental geometric measurement with the two-metre straightedge and the graduated measuring wedge, never by means of a light beam artificially held flat against the board.

What should be done if the deflection under the two-metre straightedge reaches five millimetres on a finished partition?

Check the quality grade specified in the works contract. For an ordinary normal requirement, the deviation under the straightedge must not exceed the tolerances permitted by SIA 242. If the deviation found exceeds the contractual threshold and the structural work is not the cause, the plasterer must correct the area by widening the render pass to soften the slope, then sand.

Who supplies the two-metre straightedge and the measuring wedge at plastering acceptance?

The plastering and drylining contractor must have his own calibrated inspection equipment on the construction site. To avoid any dispute about the tool's own deflection, use a two-metre straightedge made of rigid aluminium profile with a rectangular tubular section, not warped, together with a metal or hard plastic measuring wedge with clear, legible millimetre graduations.

How should joint measurements be distributed on a twelve-square-metre office partition?

Verification is not done at a single isolated point. The protocol involves applying the straightedge diagonally, horizontally at mid-height and vertically over several distinct bays, targeting in particular the joints between boards and the full board. Three to five well-distributed measurement points allow an objective diagnosis of the surface without needlessly multiplying disputed readings.

Texts and standards cited

  • norme SIA 242Plastering, rendering, drylining and suspended ceilings: surface quality grades and execution tolerances.
  • norme SIA 118General conditions for the execution of construction work: rules on the inspection of the work and the handling of defects.

In the same section