🧱 CFC 273Interior doors: installation, clearances and adjustmentChapter 6 of 10 in the section

The door closer: closing force, opening effort and accessibility

This chapter gives you the method for adjusting a hydraulic door closer on an interior frame. You will learn to size the spring force according to the dimensions of the leaf, to measure the manual effort needed to open it in line with the requirements of SIA 343, and to balance the speed-control screws precisely so that the door latches without trapping users with reduced mobility.

Key takeaways

  • The spring force must overcome air friction without exceeding the physical capacity of users.
  • SIA 343 governs the maximum efforts permitted to operate interior swing leaves.
  • The braking speed setting controls the damping over the first eighty degrees of closing.
  • The final latching action is adjusted with a screwdriver so that the latch bolt engages without striking the metal strike plate abruptly.

Adjusting the EN force size of the body to comply with the permissible opening effort

On an interior joinery construction site, installing an overhead door closer with rack-and-pinion or cam mechanism poses a recurring mechanical dilemma. On the one hand, the joiner must ensure that the leaf closes fully, overcoming the resistance of the acoustic seals, the friction of the latch bolt against the strike plate and any air pressure differences between corridors and ventilated rooms. On the other hand, an excessive return force turns the door into an impassable barrier for children or elderly people, who do not have the body mass required to push a leaf set to the maximum.

Usual correspondence between EN size of the body and leaf width
Standard EN sizeMaximum leaf widthIndicative leaf massTypical use in interior joinery
EN 1 to 2Up to 850 mmUp to 40 kgLight interior distribution doors, sanitary rooms
EN 3Up to 950 mmUp to 60 kgOffice doors, light apartment entrance doors
EN 4Up to 1100 mmUp to 80 kgHeavy apartment entrance doors, solid technical doors
EN 5 to 6Up to 1400 mmUp to 120 kgWide high-traffic doors, armoured or lead-lined doors

To reconcile these constraints, the joiner must avoid oversizing by default. Fitting a factory-preset size 4 door closer on a communicating door 830 mm wide is a common functional defect. The craftsperson uses the axial spring preload screw of the coil spring, often housed at the end of the cast-aluminium body. By loosening this screw according to the graduations provided by the manufacturer, the mechanical resistance to opening is reduced while keeping enough reserve to return the mass of the leaf.

Mastering the hydraulic circuits for braking and final latching action

Once the spring tension has been balanced with the size of the door, the physical action of the door closer rests entirely on the kinematics of its lubricating and heat-transfer fluid. The body contains two or three internal channels regulated by needle screws fitted with O-rings. The joiner works on these screws with a hex key or a thin flat screwdriver, never forcing them against the stop so as not to extrude the pressurised oil.

  1. Checking clearances and plumbBefore any hydraulic intervention, check with feeler shims the perimeter clearances of the leaf in the frame, which must be even and between 3 and 4 mm, as well as the correct operation of the hinges without parasitic friction.
  2. Setting the main closing speedWork on the primary valve screw, generally marked 1. This screw regulates the flow of oil between 180 degrees and about 15 degrees of opening. Turning it clockwise slows the movement to leave a safe passage time of about five seconds.
  3. Setting the final slam or latching actionWork on the secondary screw, marked 2, which governs the end range between 15 and 0 degrees. The aim is to give a slight acceleration to compress the sealing gasket and retract the bevel of the latch bolt without producing a violent slamming noise.
  4. Force check and reversal testCheck at the handle the resistance to initial opening with a mechanical or electronic spring scale, then test the closing release from an angle of only 10 degrees to make sure the strike plate engages without manual intervention.

Seasonal temperature variations in unheated circulation areas change the viscosity of the mineral oil. Modern models benefit from thermally compensated flow control, but a check during regular maintenance remains essential to preserve smooth operation and compliance with the requirements of the building.

Reconciling accessibility and fire-door closing in line with SIA 343

On an apartment entrance door or an interior communicating door, the joiner faces a permanent physical contradiction. On the one hand, the door must overcome the mechanical resistance of the latch bolt, crush the perimeter acoustic seals and ensure the self-closing required by fire protection. On the other hand, the mechanical resistance presented to the user must remain moderate so as not to form an impassable barrier. SIA 343 on interior doors and windows sets the requirements for operability and maximum effort, while recalling that the leaf must return to its closed position without human assistance under all service configurations.

For a person with reduced mobility or an elderly resident, exceeding a threshold of operating effort turns a distribution element into a blocking obstacle. The energy needed to open the leaf depends directly on the spring setting of the door closer, the geometry of the arm and the lever arm offered by the width of the leaf. When the installer forces the mechanical preload of the body to compensate for lock friction or excessive compression of the sealing profiles, the breakaway effort on opening increases proportionally, making the door hostile in daily use.

Selecting the standard size of the body according to the width and mass of the leaf is the first step of the trade-off. An oversized body installed on a light door of modest width imposes a penalising inertia torque from the first ten degrees of rotation. The joiner therefore takes care to choose a unit with a continuous force adjustment range, combined without fail with asymmetric cam and slide-channel technology where access for vulnerable people is a priority. This kinematics drastically reduces the resistance curve from the start of rotation compared with a traditional articulated-arm system.

On-site balancing method between mechanical latching and ease of use

Adjusting a door closer on site does not consist in turning the hydraulic needle valves at random. Any intervention requires a sequential method to separate the friction inherent to the frame from that generated by the unit itself. If the leaf shows slight warping or if the 3D hinges are poorly aligned, the door closer will never manage to engage the latch bolt without an abrupt jolt that is unacceptable in terms of noise and safety.

  1. Geometric check of the free doorTemporarily disconnect the arm of the door closer. Check with a mechanical spring scale or by hand that the leaf swings freely on its hinges without any tight spot, and that the bevelled latch bolt retracts into the strike plate without parasitic resistance.
  2. Setting the spring preloadReconnect the door closer kinematics. Define the minimum closing setting that carries the leaf to within 5 degrees of the frame, while keeping a manual opening force within the comfort tolerances.
  3. Calibrating the main sweep speedWork in quarter turns on the screw of the main hydraulic circuit regulating the travel from 90 degrees to 15 degrees. The complete cycle must offer a transit time of about 5 to 7 seconds to make passage safe for people walking slowly.
  4. Synchronising braking and final latching actionAdjust the final latching valve over the last degrees of closing. The door must accelerate just enough to overcome the lip of the fire seal and the lock latch spring, without a violent impulse or rebound against the rebate.
Diagnosing and resolving closing malfunctions
Finding on the worksMechanical or hydraulic originCorrection by the joiner
Initial opening effort excessive for the userReturn spring over-set or arm mounted with an incorrect angle of attackRelease the spring preload screw; realign the articulated arm perpendicular to the frame
The leaf stops dead on the latch bolt without lockingFinal latching action too weak against seal compression, or strike plate poorly centredOpen the latching valve by one eighth of a turn; correct the flushness of the strike plate
Violent impact against the stop and loud slammingEnd-of-travel valve opened excessively; needle screw loosened beyond toleranceGradually retighten the hydraulic latching adjustment screw to damp the arrival
Closing too fast, risking striking the userHydraulic oil too fluid in ambient heat, or main valve opened too farTighten the main speed valve; prefer thermally stable units

Disputes and adjustment deadlocks: on-site arbitration procedure

On the landings of multi-occupancy residential buildings or in medical-social institutions, the installing joiner often faces a physical conflict that cannot be resolved by manipulating the hydraulic needle valves alone. On the one hand, the accessibility requirements and SIA 343 govern the opening effort so that an elderly person or one with reduced muscular strength can pass independently. On the other hand, the compression of the intumescent sealing strips, the compression of the acoustic seals and the resistance of the latch bolt in the strike plate call for a strong mechanical return. To these factors is added the air overpressure generated by airlocks or by the mechanical ventilation of stairwells.

  1. Checking friction and air depressionsCheck the free rotation of the hinges, the plumb of the frame and the adjustment of the lower drop seal. Carry out a comparative test with the leaf open and the stairwell windows unlocked, to quantify the exact share of resistance attributable to the air flows of the building compared with frame friction.
  2. Adapting the equipment and the installation geometryValidate the size of the door closer according to the real width of the leaf. Prefer an asymmetric cam model with slide arm, whose mechanical multiplication curve softens the initial effort when pushing while keeping enough torque reserve at the end of travel to compress the seals.
  3. Written notice to site managementWhen the balance between tight closing and operability remains unattainable with a standard mechanical overhead door closer, record the reservation in writing. Propose the integration of a free-swing system coupled to the fire detection panel or the installation of a motorised electromechanical drive compliant with the safety directives.

The joiner must never under-set the spring force at the expense of secure latching of the bolt in order to mask an air overpressure. If the leaf refuses to latch without applying a setting that is too hard for users, the problem lies with the air-flow design or the choice of the overall hardware. Passing on a documented report relieves finishing work of responsibility.

Frequently asked questions

How do you measure the opening effort of a swing door on the construction site?

The check is carried out with a calibrated mechanical or digital dynamometer. The measuring hook is positioned perpendicular to the leaf, at the level of the lever handle, about 50 mm from the free edge. The craftsperson pulls the instrument continuously up to an opening of 90 degrees. Two distinct values are recorded: the breakaway force needed for the initial release of the lock, then the continuous force maintained during the angular swing phase of the leaf.

Why does a fire door no longer latch as soon as the ventilation starts?

Starting the mechanical ventilation creates an air pressure difference between the landing and the airlock or the dwelling. This air column pushes permanently against the face of the door panel, generating a resistance opposing the return spring. The door closer then lacks the kinetic energy to compress the fire seals over the last ten degrees. The solution often lies in balancing the ventilation flow rates rather than in hydraulic over-tightening.

What is the difference between a cam-technology door closer and a rack-and-pinion model?

The classic rack-and-pinion system generates a linear resistance torque: the more the user pushes the door, the more the required effort increases. Conversely, the asymmetric cam mechanism with slide arm makes the resistance drop sharply from the start of rotation. This allows an elderly person to pass through the opening with minimal push, while guaranteeing maximum closing torque at the precise moment of overcoming the latch bolt.

Can a delayed closing be fitted on a fire-rated apartment entrance door?

Yes, certified door closer bodies often offer a delayed-closing valve as an option. This additional hydraulic circuit keeps the leaf slowed or almost stationary between about 120 and 70 degrees for an adjustable duration of a few seconds. This time allows a person walking with difficulty or carrying loads to cross the opening without being subjected to the continuous pressure of the leaf, before the standard braking phase and then the final latching action are activated.

Texts and standards cited

  • SIA 343Doors and gates - Requirements and classification relating to use and operability