Key takeaways
- An access stair is essential whenever the construction site is long-term and requires carrying tools and materials by hand.
- The access deck trapdoor must imperatively be closed immediately after each user passes through.
- Spacing between scaffolding access points limits unnecessarily long horizontal travel along platforms.
- Standard SN EN 12811 specifies dimensional and structural requirements for temporary access equipment.
Selection of access systems and spacing on the structure
The choice of access equipment on façade scaffolding directly influences operative safety and manual handling ergonomics. Access via an integrated ladder with trapdoor is primarily suited to short-duration construction sites, minor works, and erection or dismantling phases. As soon as the duration of the works increases or trades (masons, tinsmiths, façade installers) must carry portable tools and small supplies up, installing an aluminium access stair becomes the required technical solution. The stair allows users to ascend levels with their hands free, maintaining a balanced posture and a steady walking speed without placing excessive strain on the upper limbs.
Standard SN EN 12811 specifies performance requirements, structural stability, and minimum dimensions for temporary construction site equipment, particularly integrated access points and stair access towers.
SN EN 12811
The layout of access points must be planned right from the layout study, based on the length of the façade and the location of workstations. Excessive spacing between two access points encourages workers to bypass safety measures or use unsafe routes. As a general rule, the horizontal walking distance along a platform level must not exceed 25 metres to the nearest access point. On long façade runs, installing multiple access towers or alternating stairs and trapdoor bays ensures smooth evacuation and a rapid retreat in the event of adverse weather.
| Access system | Preferred field of application | Manual handling | Impact on platform area |
|---|---|---|---|
| Integrated ladder with trapdoor | Erection/dismantling, short jobs, inspections | Prohibited with arms laden (hands-free required) | Retains clear width of the platform |
| Aluminium access stair in bay | Medium-duration construction sites, finishing work | Tool bags and small equipment permitted | Requires a dedicated bay or an offset |
| Independent stair tower | Structural work, long projects, heavy traffic | Simultaneous passing and smooth transport | Ground footprint external to the scaffolding |
Technical erection arrangements and inspection of openings
The erection of an access bay or stair tower must follow strict rules regarding alignment and anchoring. According to art. 26 OTConst, façade scaffolding must be installed as soon as the fall height exceeds 3 m, with a top guard rail extending at least 80 cm above the edge of the highest area presenting a fall risk. For access routes, the stair handrails and internal guard rails must connect seamlessly with the peripheral guard rails of the main platform.
- Checking ground stabilityRest the access bay on wooden sole plates of appropriate thickness and adjust the base jacks to ensure the standards are perfectly vertical.
- Installing trapdoor decks and laddersInstall access decks by alternating the direction of the trapdoors depending on the configuration, or by mounting ladders at the manufacturer's recommended inclination.
- Securing stair guard railsInstall the intermediate guard rail, stair handrail, and specific access toe board to fully close off the lateral opening.
- Reinforced anchoring of the access bayDouble the anchors at the access tower to absorb dynamic forces caused by repeated traffic from users.
During the daily scaffolding inspection prior to handover to the trades, the site manager or lead erector checks the condition of the trapdoor latches, verifies that the stair stringers are free of distortion, and ensures the non-slip treads are clean. Any distorted component preventing complete closure of a trapdoor must be replaced without delay. The prohibition against storing materials or debris on trapdoor decks is one of the fundamental safety rules displayed at the foot of the scaffolding.
Choosing an access system according to duration and intensity of use
Determining the access system for façade scaffolding must not be left to improvisation on the construction site. It depends directly on the duration of the works, traffic frequency, and the nature of loads carried by the trades required to work on the platforms. Standard SN EN 12811 defines performance requirements and dimension classes for temporary access equipment, establishing a clear distinction between routes intended for simple inspection and those designed for regular material transport.
For long-term construction sites or those with heavy personnel traffic, an integrated or attached stair tower is the benchmark solution. It allows vertical transit with hands free, reducing physical strain and the risk of missteps when carrying portable tools. Access via an inclined ladder with a trapdoor remains reserved for light work, very short-term projects, or secondary, low-traffic areas of the decking.
| Technical criterion | Integrated ladder with trapdoor | Scaffolding stair (tower or bay) |
|---|---|---|
| Traffic frequency | Low to medium (inspection, occasional work) | High (frequent back-and-forth travel by multiple workers) |
| Material handling | Prohibited with hands laden (hands-free required on rungs) | Permitted for small tools carried in a bag or by hand |
| Inclination and geometry | Steep inclination (70° to 75°), narrow stiles | Gentle slope (45° to 50°), non-slip treads with handrails |
| Opening safety | Requires rigorous manual closure after every transit | Continuous passage outside the working volume of the decking |
Operational safety, trapdoor closure and access spacing
Using a trapdoor access requires strict site discipline. A trapdoor left open in a decking creates an unguarded floor opening, turning the working plane into a fatal danger zone for trades working on the platform above. The Construction Works Ordinance reiterates in OTConst art. 26 that scaffolding must provide comprehensive fall protection. Closing the trapdoor is the only way to ensure unbroken continuity of the working surface after an erector or user passes through.
Horizontal spacing between access points along a façade must be planned right from the erection of the temporary structure. Excessive spacing tempts workers to take hazardous shortcuts, climb over guard rails, or step over tie points inappropriately. Conversely, a well-distributed density of access points smooths movement, reduces travel times on scaffolding platforms, and improves emergency evacuation in the event of an accident on the construction site.
During the acceptance of the work for the scaffolding, the lead erector inspects the condition of each trapdoor, the proper functioning of hinges, the firmness of latches, and the fastening of the ladder below platform level. Access handrails and guard rails must be continuous and free of sharp edges. If a non-conformity is identified on an access point, the bay concerned must immediately be taken out of service with a 'no access' sign until it has been rectified.
Managing defects, access compliance and maintenance
On the construction site, damage to or misuse of scaffolding access points represents the main source of risk during vertical movement. A damaged trapdoor spring, an unlatched access deck, or the unauthorised removal of an integrated ladder immediately renders the installation non-compliant. In accordance with the requirements of standard SN EN 12811, each access system must remain functional, free of obstructions, and maintained in perfect working order throughout the entire period the temporary structure is made available.
When the progress of the construction site generates heavy daily worker traffic or regular manual carrying of small tools, access via an integrated ladder reveals its ergonomic limitations. Installing an aluminium access stair tower becomes essential whenever use becomes prolonged or intensive. This allows finishing work trades to ascend while keeping their hands free to hold the handrail.
| Inspected item | Defect observed | Required action on site |
|---|---|---|
| Integrated access trapdoor | Jammed closing mechanism or broken spring | Immediate replacement of the trapdoor deck. |
| Inclined / integrated ladder | Distorted or improperly locked rungs | Take access bay out of service and repair. |
| Aluminium access stair | Missing guard rail or handrail | Erect side protection according to SN EN 12811. |
| Spacing of access points | Distance between two access points exceeds 25 metres | Add an intermediate access tower. |
The employer continuously adapts organisational measures so that access remains safe pursuant to LAA. Repairs to access components must be carried out exclusively by qualified scaffolding erectors. The supply and erection of supplementary access towers are subject to additional quantity surveying, the costing basis for which can be consulted under /soumissions/.
Frequently asked questions
When must an integrated ladder be replaced with a stair access tower?
A stair tower is required as soon as the construction site involves frequent ascent and descent by personnel, prolonged use by several trades, or the need to carry small tools by hand. The stair improves ergonomics, allows workers to ascend hands-free using the handrail, and significantly reduces physical fatigue compared to repeated transit via trapdoors and ladders.
Who is responsible for closing the access trapdoor after each transit?
Every user working on the scaffolding must close the trapdoor immediately after passing through it. This prevents people from falling through the scaffold deck. If a defective mechanism prevents the trapdoor from closing, the fault must be reported to the site manager without delay so the component can be replaced by the scaffolding erector.
What is the maximum permitted spacing between two access points on façade scaffolding?
According to good trade practice and technical recommendations based on standard SN EN 12811, the spacing between two access points should not exceed 20 to 25 metres along the façade. Excessive distance unnecessarily lengthens emergency evacuation routes and encourages workers to climb the framework, which is strictly prohibited.
Can integrated ladders be used to carry heavy equipment up?
No. Using an integrated ladder and trapdoor requires keeping both hands free to maintain three points of contact when ascending or descending. Transporting heavy materials or tools must be carried out exclusively using suitable mechanical lifting equipment, construction hoists, or mobile elevating work platforms.
Texts and standards cited
- SN EN 12811Temporary works equipment - Performance requirements and general design of scaffolding structures
- OTConst art. 25Openings in floors and protection against falls
- LAAObligations of employers and workers regarding accident prevention