Mobile, Suspended, and Temporary Structures: Execution Standard
Aimed at scaffolding erection chargehands, foremen, and site managers, this section compiles execution rules for all temporary structures outside standard facades. From wheeled mobile towers to powered suspended platforms, through temporary roofs and protected walkways on public land, it details structural sizing, support connections, structural anchoring, and erector safety against specific overturning and fall hazards.
- 10chapters
- 22 000words
- 6sections in the training course
- 60chapters in total
Key values to remember 5
2 m
Fall height above which appropriate fall protection measures must be taken along roof edges
60°
Roof pitch above which work may only be carried out from scaffolding or an elevating work platform
100 cm
Minimum height of the upper edge of the top guardrail on an edge protection system
15 cm
Minimum height of the toeboard on an edge protection working guardrail
47 cm
Maximum permissible vertical clear gap between longitudinal guardrail elements
Technical Scope of Temporary Structures and Competence Limits
This section covers exclusively the erection, adaptation, conformity inspection, and dismantling of special temporary structures falling within the direct competence of scaffolding erectors (CFC 212). These structures differ from standard straight facades due to their specific mechanical loads: significant cantilevers, dynamic wind loads on temporary roofs, mobility of loads on castors, or complete offset on traction wire ropes. They demand superior execution rigour whenever direct ground support is lacking or building geometry requires complex bridging.
Working on these structures often departs from manufacturers' standard configurations. As soon as a mobile tower exceeds the dimensional limits of standard SN EN 1004 or a suspended platform rests on historic parapets, the erector must have the load descent and force transfers validated by an engineer's structural calculation sheet. Under OTConst, when it is technically impossible or too hazardous to erect standard collective fall protection, equivalent measures must be defined in writing by consulting an occupational safety specialist.
| Structure type | Primary load | Critical inspection point | Reference standard |
|---|---|---|---|
| Mobile tower | Dynamic overturning | Wheelbase and castor wheel locking | SN EN 1004 |
| Suspended platform | Tension and pull-out | Counterweights and safety wire rope | OMach, RS 819.14 |
| Cantilever scaffolding | Bending and shear | Load-bearing capacity of anchor plugs and transoms | Construction Work Ordinance |
| Temporary roof (umbrella) | Wind uplift | Ballast, tie-backs, and sheeting continuity | Safety engineering standards |
Technical Progression: From Mobility to Heavy Protection
The chapter sequence has been designed to structure site working methods, starting from lightweight self-supporting systems and progressing towards structures with heavy structural load transfers. The erector starts by mastering the equilibrium of ground-based mobile equipment with mobile access towers [E5-01], where base geometry and the strict prohibition of moving towers with personnel aboard form the baseline rules. The progression then tackles overhead suspension techniques [E5-02] and cantilever platforms anchored into masonry or concrete [E5-03], two cases where verifying the host structure conditions team survival.
The second part addresses large-span enclosures and public interactions. Temporary roofs, known as umbrellas [E5-04], require in-depth analysis of horizontal and vertical weather forces. Covered walkways in urban environments [E5-05] introduce strict requirements for clearance profiles, impact resistance against falling materials, and municipal permits for encroachments on public property.
- Confined Spaces and Internal DeckingChapters [E5-06] and [E5-07] guide erection inside narrow stairwells and the installation of safety net arrays below roof structures, arresting falls from the underside without continuous points of support.
- Heavy Structures and Exceptional LoadsChapters [E5-08] and [E5-09] cover temporary shoring of historic facades subjected to wind loads after internal demolition, as well as staging receiving heavy dynamic public live loads.
- Work on Steep SlopesChapter [E5-10] concludes the series on working on pitched roofs according to art. 41 OTConst, detailing the use of roof brackets, tinsmith platforms, and temporary lifelines.
📘 Chapters in this section 10
Mobile scaffolding: outriggers, permissible height, and empty moving
Secure the wheelbase, adjust outriggers, and move mobile towers without risking overturning.
Mobile, suspended and temporary structuresSuspended platform: suspension jibs, counterweights and cable fall arrester
Calculate davit counterweights and lock secondary rope fall arresters to work suspended safely.
Mobile, suspended and temporary structuresCantilever scaffolding: transferring load to the existing structure
Size brackets and anchor plugs to transfer heavy cantilever loads safely into concrete.
Mobile, suspended and temporary structuresTemporary roof scaffolding: covering a roofing site during works
Erect a weathertight, wind-resistant temporary roof to protect an exposed timber framing site.
Mobile, suspended and temporary structuresCovered pedestrian walkway: clearance, lighting and municipal permit
Set up a pedestrian tunnel meeting statutory clearances, with robust lighting and impact-resistant decking.
Mobile, suspended and temporary structuresInternal scaffolding in stairwells: flight supports and void protection
Erect stable scaffolding on spiral or straight stair treads without obstructing required escape routes.
Mobile, suspended and temporary structuresUnderside safety netting: fall height, attachment points and overlap
Install safety nets under roof trusses with correct mesh sizes, drop heights, and certified anchor points.
Mobile, suspended and temporary structuresShoring a retained façade: raking shores, ballast, monitoring
Design heavy-duty propping using raking shores and ballast blocks to support a freestanding facade.
Mobile, suspended and temporary structuresTemporary Grandstands and Stages: Public Load, Guardrails, and Authorisation
Assemble stages and grandstands for public use complying with dynamic live loads and reinforced guardrails.
Mobile, suspended and temporary structuresWorking on a pitched roof: roof scaffolding, safety hooks and lifeline
Install roof brackets, fall-arrest anchors, and safety hooks to carry out work on steep roof pitches.