Skip to content
Website
🧱 CFC 201 / 211.0SUVA safety, health and workstation requirementsChapter 4 of 10 in the section

Manual Handling in Masonry: Reasonable Limits and Lifting Aids

This chapter provides the tools to eliminate heavy manual handling on your structural work construction sites. You will learn to identify critical thresholds per unit, select suitable lifting aids — grabs, jibs, and vacuum lifters — and organise workstation supply to reduce physical wear and tear on teams without compromising daily output.

Key takeaways

  • SUVA guidelines establish strict benchmarks to prevent disabling lumbar injuries.
  • Any element exceeding twenty-five kilograms requires mechanical lifting or trolley-guided handling.
  • Vacuum lifters and block grabs eliminate direct physical strain on precast materials.
  • Storage logistics located as close as possible to masons drastically reduce unnecessary manual transfers.

Critical Loads in Masonry and SUVA Action Thresholds

On a masonry construction site, repetitive heavy lifting prematurely damages workers' lumbar discs. Time off work due to a herniated disc disrupts the team and severely impacts the company's claims record. Pursuant to art. 82 LAA, the employer is required to take all necessary preventive measures that are suited to site conditions and feasible according to the state of the art. SUVA points out that continuous carrying exceeding 25 kg for an adult male must be avoided through organisational measures or mechanical aids, with these limits decreasing drastically as soon as the load moves away from the trunk or requires twisting.

Unit Weights of Common Materials and Required Handling Devices
Element or materialIndicative unit weightPrimary physical strainRequired handling method
Standard clay brick (modular)9 to 14 kgRepetitive motion, single-handed gripManual laying, direct supply at waist height
Large-format sand-lime block20 to 35 kgCarrying at arm's length, lumbar flexionLifting grab on mobile jib or mini crane
XXL aerated concrete wall element50 to 120 kgLoad cannot be carried manually without acute riskDedicated installation trolley with vacuum spreader beam
Concrete kerbstone (1 m)90 to 130 kgLifting off the ground, crushing hazardMechanical grab on lorry loader crane or mini-excavator
Bag of cement or ready-to-use mortar25 kgRepetitive unloading, torso rotationAll-terrain forklift, pallet storage at working height

Ergonomic analysis demonstrates that the purchase or hire cost of a technical aid is amortised within the very first square metres laid. Protecting spinal health prevents long-term sick leave, the indirect costs of which far exceed the investment in self-clamping grabs or scaffolding jibs. The Ordinance on the Prevention of Accidents and Occupational Diseases also requires the application of recognised occupational health rules to limit these strains.

Technical Lifting Aids and Spatial Organisation of the Workstation

Integrating mechanical grabs, masonry jibs, and vacuum lifting devices revolutionises the bricklaying station. Motorised or battery-powered vacuum lifters allow instant gripping of airtight elements such as precast concrete slabs or large-format blocks, without pinch hazards for fingers. This equipment reduces muscular adjustment effort while increasing laying rates without cumulative fatigue.

  1. 1. Pallet positioning by craneLand masonry pallets directly onto floor slabs in the immediate vicinity of the laying area, verifying the slab load-bearing capacity to avoid excessive load concentrations.
  2. 2. Use of an all-terrain pallet truck or pallet lifterDistribute materials as close as possible to the mason to eliminate carrying loads on foot. Keep travel paths level and clear of any debris.
  3. 3. Element pick-up by mechanical aidEngage the vacuum lifter or position the balanced clamp grab onto the block without bending the spine, guiding the element using ergonomic handles.
  4. 4. Placement and adjustment on mortarLower the element onto its bed of mortar or adhesive with support from the jib, checking alignment with a spirit level without supporting the dead weight of the material.

The site foreman must ensure strict maintenance of vacuum lifter sealing gaskets and periodic inspection of lifting slings or straps, in compliance with the Ordinance on the Safety of Machinery. A suction cup soiled with cutting dust loses its gripping capacity and endangers the operator. Mechanising handling stabilises the daily output of the team while ensuring that masons return home uninjured at the end of the day.

Unit Weights of Materials and Biomechanical Limits at the Workstation

On structural work construction sites, repetitive carrying of masonry blocks is the primary cause of chronic lower back pain and herniated discs among masons. The assessment of physical strain is not limited to gross mass: it includes gripping frequency, distance from the body, and placement height. According to art. 82 LAA, the employer must take all necessary measures shown by experience to be required and made feasible by technical progress to protect worker health. In daily practice, a mason laying heavy elements routinely handles between 4 and 8 tonnes of materials per shift without mechanical assistance.

As soon as an element exceeds this value or requires an asymmetrical lift with outstretched arms, single-person manual handling becomes unacceptable. Unloading pallets on the ground for subsequent manual lifting to scaffolding or platforms multiplies cumulative tonnage unnecessarily. The following table summarises typical weights encountered in building masonry and the minimum assistance equipment required to comply with occupational health guidelines.

Classification of Common Masonry Elements and Prescribed Handling Methods
Element or materialTypical format (cm)Indicative unit weightLaying method and required equipment
Standard clay brick (modular)25 x 12.5 x 146 to 9 kgManual single-handed laying, direct supply at waist height
Large-module sand-lime block50 x 20 x 2528 to 38 kgMandatory mechanised laying: lifting grab on mini crane or jib
Shuttering concrete block (hollow core)50 x 20 x 2018 to 24 kgManual two-handed laying provided a platform is used, or mechanical grab
Precast clay or concrete lintelLength 120 to 25035 to 80 kgTeam lifting with two workers or slinging under crane hook
Kerbstone or coping element100 x 25 x 1570 to 110 kgMechanical kerb grab on machine or self-contained vacuum lifter

Technical Aids, Vacuum Gripping, and Supply Logistics

To eliminate destructive manual handling without compromising site output, companies rely on workstation mechanisation. Installing a mobile jib on the slab or an electric mini crane with a hydraulic grab enables a single mason to lay heavy sand-lime blocks at a sustained pace. The use of equipment complying with the Ordinance on the Safety of Machinery (OMach, RS 819.14) guarantees the reliability of overload and guidance safety features.

For smooth or airtight surfaces such as precast slabs, landing steps, glass panels, or architectural precast concrete elements, the vacuum lifter is the reference tool. Modern vacuum lifters operate with a self-contained battery-powered vacuum generator equipped with a visual and audible alarm indicating any loss of pressure. Art. 3 OPA prescribes the use of equipment conforming to recognised technical rules to prevent falling objects during suspended transport.

  1. Staging planning by work progress zoneDetermine pallet positions directly on the formwork plan prior to pouring the floor slab below, checking allowable load capacity to prevent excessive load concentration.
  2. Supply by crane at table heightProhibit storing blocks on the ground. Place pallets on robust trestles or metal risers so that the first and last rows can be picked up between mid-thigh and chest height.
  3. Deployment of balancing grabs and jibsInstall the wheeled mini crane or telescopic-post-mounted jib as close as possible to the wall under construction, covering a 4 to 6 metre working radius without moving the base.
  4. Inspection of gripping accessoriesInspect the seal on rubber suction pads daily and check the cleanliness of block grab gripping jaws prior to any suspended operation.

The spatial layout of the workstation must prohibit manual carrying of materials over distances greater than two metres. The site foreman ensures that the brick trolley or all-terrain pallet truck delivers units right to the laying station. Minimising manual transport over cluttered ground prevents trunk twisting, a primary cause of loss-of-balance accidents on masonry construction sites.

Supply Failures and Ergonomic Bottlenecks: Procedure to Follow

On a structural work construction site, a breakdown in the mechanised handling chain requires an immediate management response. When a tower crane breaks down, a telehandler is immobilised, or a vacuum lifter fails to grip due to an overly rough surface, reverting to mass manual carrying is an organisational failing. Pursuant to art. 82 LAA, the employer must implement all necessary preventive measures adapted to actual production conditions to protect the physical integrity of staff. If heavy elements cannot be lifted mechanically, the site foreman must halt work on the affected laying front.

  1. Immediate zone freeze and failure analysisHalt work as soon as an individual unit exceeds safe manual handling capacities. Strictly prohibit the manual carrying of dense sand-lime blocks, kerbstones, or precast lintels.
  2. Logistical and equipment reorganisationCall the construction site mechanic or hire company technical service. In the event of a prolonged stoppage, temporarily reassign the team to preparatory tasks that do not strain the back, such as chalk line marking or light steel reinforcement.
  3. Use of backup equipmentDeploy suitable mechanical lifting grabs, a jib hoist, or adjust pallet positioning using an all-terrain pallet truck to reduce remaining horizontal carrying distances to the absolute minimum.

If the issue stems from packaging incompatibility not notified by the supplier, the site manager must formalise the logistical defect immediately. According to CO, the contractor must promptly notify the client whenever supplied materials or external circumstances jeopardise the regular execution of the works. Receiving precast elements lacking certified lifting points justifies refusing delivery. Improvising with non-compliant slings exposes the team to violent restraint forces and crushing hazards incompatible with Swiss trade standards.

Frequently asked questions

What should be done if the vacuum lifter loses suction on damp masonry blocks?

The installation manoeuvre must be stopped immediately and the load lowered back to the ground. Residual moisture and cement dust compromise the seal of the suction pad lips. The team must thoroughly clean the contact surface, check the vacuum filters, and verify the pressure gauge. If the technical problem persists, replace the vacuum lifter with a gravity-lock mechanical grab suited to the block dimensions.

How should one react if the lorry unloads pallets of bricks too far from the masonry workstation?

The chargehand must reject placement outside the designated zone and demand immediate repositioning by the driver or using the site's telehandler. Moving bricks manually across a slab causes critical spinal fatigue and massive productivity losses. Supply must always be delivered within direct reach of the crane or within the immediate working radius of the masons.

Can a mason refuse to install precast lintels without lifting equipment?

Yes, the worker must report the situation and request suitable equipment if a lintel exceeds safe carrying capacity. Manual handling at shoulder height causes extreme spinal disc pressures prohibited by SUVA guidelines. The site manager is required to provide a lightweight hoist, a mobile workshop crane, or call in the tower crane with compliant slings.

Who bears the cost of a lifting grab that was not planned in the tender?

Tools and handling aids form part of the standard operating expenses of the masonry contractor, included in site overheads. However, if site management mandates an unforeseen change to oversized precast elements during execution, the contractor must submit an addendum for the adaptation of specific lifting equipment before any work is carried out on the construction site.

Texts and standards cited

  • LAA art. 82general prevention rules: the employer must take, to prevent occupational accidents and diseases, all measures shown by experience to be necessary, feasible according to the state of the art, and adapted to the given conditions; workers must assist the employer (notably by using personal protective equipment).
  • COmaterials and site conditions: the contractor is responsible for the good quality of materials provided by him; if the material supplied by the client or the site designated by him is found to be defective, or if any other circumstance jeopardises the regular or timely execution of the work, the contractor must inform the client immediately, failing which he will bear the consequences (para. 3).

In the same section