Upon receipt as well as in the workshop, a steel section exhibits residual deflections. This chapter teaches you how to measure straightness deviations rigorously to standard SN EN 1090, identify permissible tolerances for your structural steelwork, and select cold or hot straightening methods without degrading the steel grade.

Key takeaways

  • Straightness checks are systematically carried out on a surface plate or trestles using a taut wire.
  • Execution tolerances specified by SN EN 1090 distinguish functional classes from essential criteria.
  • Mechanical straightening under a cold press remains limited by the material's permissible plastic elongation.
  • Flame straightening using a blowpipe requires strict temperature management to avoid scrapping components.

Receiving Raw Sections and Verifying Permissible Straightness

Standard rolled beams and hollow sections delivered from mills or stockists routinely exhibit axial deviations resulting from rolling, asymmetric cooling, or handling. Prior to any cutting or machining, the site foreman must inspect the incoming material to verify its overall geometric compliance. Material receipt is not limited to checking the delivery note and mill test certificate; it requires a physical inspection of each bar intended for load-bearing structural members in structural steelwork or heavy façades.

  1. Positioning the barPlace the section freely on stable trestles or on a level layout surface plate, free from external loads or torsion induced by cantilevered storage.
  2. Setting up the reference axisStretch a steel wire or piano wire over calibrated shims placed at both ends of the chord, or use a precision aluminium straightedge.
  3. Measuring the maximum deflectionUsing a steel rule or depth gauge, measure the maximum deviation observed between the wire and the steel surface, typically located at mid-span.
Common straightness tolerances according to standard SN EN 1090 for compression members
Structural elementGeometric criterionPermissible toleranceInspection note
Main column or compression chordOverall deflection over length LL / 1000Essential tolerance for buckling stability
Standard floor beamDeviation along major axisL / 500Functional alignment criterion
Composite façade beamLateral deviation along minor axisL / 750Alignment criterion for mullion fixing

Identifying an out-of-tolerance section requires notifying the client before making irreversible alterations. Under art. 365 CO, if the material supplied by the client or the site designated by him proves defective, or if any other circumstance compromises the proper or punctual completion of the work, the contractor must inform the client immediately. Where the steel originates from the workshop's own stock, the decision to reject the batch or correct it in-house remains a matter of production costs.

Straightening a Section: Cold Methods, Flame Straightening, and Standard Limits

When the deflection defect exceeds permissible limits but remains moderate, the steel fabricator can employ controlled straightening. Two workshop techniques are standard: cold mechanical action using a press brake or profile bending machine, and targeted thermal input by flame heating with an oxy-acetylene blowpipe. Each of these methods modifies the internal state of the material and must comply with strict rules set out in standard SN EN 1090.

Flame straightening
Operation consisting of locally heating a triangular or trapezoidal area of the flange or web of a steel section. The metal, expanding under plastic restraint, contracts upon cooling, thereby straightening the member's axis.
  • Cold mechanical straightening: reserved for gradual deformations without sharp kinks; local plastic deformation must not exceed the permissible bending radii of the steel grade.
  • Flame temperature monitoring: compulsory use of thermo-sensitive crayons or an optical pyrometer to monitor the temperature range during flame straightening.
  • Natural cooling: water spraying or the use of compressed air is strictly prohibited to prevent the formation of brittle martensitic microstructures.
  • Prohibition on pretreated sections: any hot straightening on painted, blast-cleaned, or galvanised elements is prohibited without prior and complete stripping of the affected area.

Once the operation is complete and the section has stabilised at ambient temperature, a full second dimensional check must be documented in the quality assurance file. If the component displays web rippling, flange lateral distortion, or micro-cracks revealed by liquid penetrant inspection following mechanical working, the workshop manager must reject and scrap the component. On the construction site, forced corrections using a cable winch (tirfor) during bolting are prohibited because they introduce hazardous residual stresses into the entire load-bearing system.

Straightness Tolerances to Standard SN EN 1090 and Non-conformity Management

Receiving a standard hot-rolled section or plate girder (PRS) in the workshop requires rigorous verification of its geometry prior to any cutting or drilling. No mill-delivered section is entirely free of residual camber or sweep. For structural members incorporated into load-bearing frames, the Swiss normative framework relies on standard SN EN 1090-2, which specifies essential and functional tolerances applicable to manufacturing. These criteria ensure that compression or bending forces do not trigger unforeseen elastic instabilities during site loading.

Straightness checks are systematically carried out on a stress-free test bench without clamping fixtures. Workshop teams stretch a steel wire or place a calibrated straightedge along the main generating lines: major axis (deflection yy) and minor axis (deflection zz), as well as twist along the member. If the component exceeds normative thresholds, the steel fabricator must evaluate whether the defect originates from the rolling mill or from welding operations, and then decide upon a validated rectification procedure.

Maximum permissible straightness deviations in fabrication according to standard SN EN 1090-2
Type of structural elementGeometric parameterEssential tolerance (stability)Functional tolerance (appearance/interface)
Compression column (HEB, HD, hollow section)Deflection on buckling axis (L)Δ = L / 1000 (not exceeding 10 mm)Δ = L / 750
Bending beam (IPE, HEA)Lateral deflection of compression flangeΔ = L / 1000Δ = L / 500
Plate girder (PRS)Web flatness between stiffeners (b)d = b / 100d = b / 150
Load-bearing steel façade transomOverall straightness in glazing planeΔ = L / 1000Δ = 3 mm over each 2 m span

Whenever a beam or column exceeds these values, the element is placed on hold in a quarantine area. The steel cannot be incorporated into the works under the assumption of subsequent mechanical pull-back when tightening preloaded HR bolt assemblies: forcing a twisted section into alignment during erection introduces parasitic stresses that impair its load-bearing capacity.

Operating Rules for Thermal and Mechanical Straightening in the Workshop

The choice between cold straightening and thermal straightening depends on flange thickness, steel grade, and the selected execution class. Uncontrolled plastic deformation alters the material's impact properties and modifies the residual stress field. In the workshop, the team leader implements qualified procedures and logs each operation into the factory production control file.

  • Cold mechanical straightening: performed on hydraulic roller levellers or under a press using rounded supports. It is limited to moderate deflections to prevent excessive strain hardening or micro-cracking of outer fibres in steel grades S235 to S355.
  • Hot straightening (flame straightening): localised heating using an oxy-acetylene blowpipe in triangular heating wedges or longitudinal heating lines. The contraction of the heated area upon cooling pulls the member back into theoretical alignment.
  • Temperature monitoring: mandatory monitoring using thermo-sensitive crayons or an infrared pyrometer. Heating temperatures must not exceed 650 °C for thermomechanically rolled steels (S355M/ML) and 700 °C for normalised steels (S355J2+N) to prevent degrading metallurgical heat treatment.
  • Natural cooling: any forced water cooling is strictly prohibited on structural members of load-bearing frames; cooling must occur slowly in still air to prevent brittle martensitic formations.

When straightness defects stem from non-compliant material supplied by the rolling mill or stockist, the workshop manager drafts a non-conformity report. Under art. 365 CO, the contractor notifies the client or their representative of defects identified in the supplied material that compromise the proper execution of the works. If mechanical or thermal straightening risks impairing the mechanical properties guaranteed by the 3.1 mill test certificate, the section must be rejected and replaced prior to any end-welding operations.

Straightness Disputes and Managing Critical Non-conformities

On the workshop surface plate or during the incoming inspection on the construction site, the measured deflection of a rolled section sometimes exceeds the straightness tolerance established by standard SN EN 1090-2. When faced with an unacceptable geometric deviation, the workshop manager or site supervisor must stop cutting or erection to prevent initiating irreversible fabrication work. Managing the dispute directly depends on the steel grade and the operations already performed on the bar.

If the defect originates from the mill or stockist, delivery of the raw steel is rejected and endorsed on the consignment note, accompanied by a joint inspection report recording deflections using a wire and steel rule. In the case of client-supplied material or bars already cut, the steel fabricator applies the rules of the Code of Obligations (CO) regarding material defects. Under art. 365 CO, if the material supplied by the client or the site designated by him proves defective, or if any other circumstance compromises the proper or punctual completion of the work, the contractor must inform the client immediately.

  1. Record and traceabilityRecord the deflection relative to the total length, identify the cast number on the 3.1 mill test certificate, and log the dimensions in the internal non-conformity report.
  2. Evaluation of straightening feasibilityVerify the grade. Thermomechanically rolled or high-yield-strength steels preclude unconstrained flame straightening with a blowpipe. Only a roller press or a cold jacking rig can be considered in such cases.
  3. Technical procedure approvalSubmit the technical repair procedure to the structural engineer responsible for the load-bearing framework prior to applying any heavy thermal or mechanical processes.
  4. Scrapping or replacementWhen the force required for straightening risks inducing critical strain hardening, crack initiation, or unacceptable residual stresses, the member is scrapped and replaced.

Frequently asked questions

How is the straightness of a heavy section rigorously measured upon delivery?

Measurements are taken on a flat reference surface or on shims of equal height placed at the ends. Stretch a steel wire or fine cord between both ends of the section, then measure the maximum offset at mid-span using a graduated steel rule, across both the major and minor axes. This measured deflection is then compared against permissible ratios established for the project's execution class.

Can a distorted thermomechanically rolled S355 steel section be hot-straightened?

Flame straightening using a blowpipe is strictly prohibited or severely restricted on grades supplied in a thermomechanically rolled condition, such as S355M. Uncontrolled heat input irreversibly alters the metal's microstructure and degrades its yield strength and toughness. For this type of grade, cold mechanical straightening under a hydraulic press is preferred, provided that permissible bend radii are respected.

What should be done if a steel column delivered to the construction site exhibits an out-of-tolerance curvature?

Never attempt to force the member into alignment during erection by over-torquing anchor rods or splice bolts. Report the defect in writing to site management and quarantine the element. The structural engineer must determine whether the member can undergo controlled cold straightening in a specialised workshop or whether it must be returned to the manufacturer for full replacement at the responsible supplier's expense.

Who bears the cost of straightening necessitated after welding a plate girder?

Distortions induced by thermal shrinkage from welding are standard fabrication constraints in structural steelwork. Their workshop correction using calibrated flame straightening or under a press is entirely the responsibility of the steel fabricator. These operations must be accounted for in the welding sequence design and factored into production costs, with no grounds for claims against the client.

Texts and standards cited

  • SN EN 1090-2Execution of steel structures and aluminium structures - Technical requirements for steel structures
  • CO art. 365Material and ground: the contractor is liable for the proper quality of the material he supplies; if the material supplied by the client or the ground designated by him proves defective, or if any other circumstance compromises the proper or punctual completion of the work, he must inform the client immediately, under penalty of bearing the consequences (para. 3)