Applying a paint system without harming the health of your workers or polluting the environment demands methodical rigour. This section is aimed at team leaders and site managers who manage solvent exposure, the choice of protective equipment, waste traceability and coexistence on the construction site, in accordance with SUVA directives and federal worker-protection ordinances.

  • 10chapters
  • 22 000words
  • 6sections in the training course
  • 60chapters in total

Key values to remember 4

OTConst art. 33

19 to 21 %

Minimum and maximum volume content of oxygen required in the ambient air at the workstation

OTConst art. 23

2 m

Free-fall height from which collective fall protection is mandatory

SUVA publication: Occupational exposure limit values at workplaces

0.02 mg/m³

Usual order of magnitude of the occupational exposure limit value for monomeric diisocyanates

CO

60 days

Legal period within which the client must report defects discovered in a building work

The painter's technical scope: what falls under your responsibility

The trade of painter and wall-covering applicator (CFC 272) focuses on fine preparation of substrates, application of primers, paints and varnishes, and fitting of flexible or decorative wall coverings. Your operational responsibility begins as soon as you receive a clean, dry and mechanically sound substrate. Under the Swiss prevention rules and LAA, the employer must implement all protective measures appropriate to the state of the art, while workers follow the instructions and wear personal protective equipment.

To avoid disputes on the construction site and clarify the contractual interfaces, the demarcation with neighbouring trades must be strictly respected by the trade management:

  • Plastering and false ceilings (CFC 271): the plasterer delivers surfaces to an agreed finish grade (Q1 to Q4). The painter checks this flatness visually and by touch and notes any flushness defects, but does not rework a plasterboard panel that is not flat.
  • Façades and external insulation (CFC 221): the façade contractor carries out the thermal insulation and its mineral or organic reinforcing render. The painter intervenes only on dry render for levelling coats, siloxane protection or exterior refresh coats.
  • Metalwork (CFC 215): heavy stripping by blasting and workshop anticorrosion primers are the responsibility of the metalwork contractor. The painter handles adhesion touch-ups on the construction site and decorative finishing coats.
  • Floor coverings and parquet (CFC 281 and 283): floor levelling, screed production and CM moisture checks belong to the screed layer. Heavy sanding and varnishing of a solid parquet fall to the parquet layer. The painter applies only film-forming resin floor paints on a sound, accepted slab.

Discharge management is the second pillar of your responsibility: fresh paints, dirty solvents and cleaning sludge must never enter public clean-water or wastewater drains. All residues must be identified in accordance with the waste ordinance and sent to approved specialist treatment channels.

Logical reading order and operational progression

To organise your construction sites safely, economically and in line with SUVA requirements, this section follows the execution chronology of a project, from chemical risk assessment through to the clean removal of installations.

  1. 1. Controlling the application environment and the chemistry (O6-01 to O6-04)Start by sizing the air renewal in an enclosed room, where art. 33 OTConst applies to maintain a compliant oxygen level and dilute hazardous substances. Then select the appropriate respiratory protection cartridges (A vapours and P3 dust), prescribe suitable nitrile gloves to avoid skin sensitisation, and make effective use of the key sections of the safety data sheet.
  2. 2. Securing workstations and equipment (O6-05 to O6-08)Set up ventilated storage areas for flammable products while avoiding thermal shocks. Introduce rotation of rinsing solvents by settling in order to reduce consumption of new products, strictly supervise the treatment of roller wash water, and ban prolonged use of stepladders in favour of compliant, secured platforms.
  3. 3. Managing occupied construction sites and preventing defects (O6-09 and O6-10)Plan work in occupied dwellings by neutralising residual odour nuisances, then structure the prior substrate control chain to formalise your written duty to notify before any risk of blistering on masonry work.

📘 Chapters in this section 10

Products, VOCs, health and the painter's site

Working in a closed room: forced ventilation, heavy vapours and limit values

Calculate the extraction rate required to remove dense vapours during work in basements.

Products, VOCs, health and the painter's site

The right filter: organic vapours, particles, combined mask and service life

Identify the exact cartridge against organic gases and know when to replace it by touch.

Products, VOCs, health and the painter's site

The skin: nitrile gloves, sensitising hardeners and occupational eczema

Prevent incurable occupational dermatitis by choosing the glove thickness suited to reactive resins.

Products, VOCs, health and the painter's site

The safety data sheet: the four sections you actually read

Locate in thirty seconds the vital sections needed to complete labelling and adapt protection.

Products, VOCs, health and the painter's site

Storing products: frost, heat, flammables and closed rooms

Set up a compliant construction-site store to protect your drums from frost and avoid ignition.

Products, VOCs, health and the painter's site

Cleaning tools: roller kept, spray gun flushed, solvent reused and settled

Implement methodical settling to recover your thinners and protect your pumps.

Products, VOCs, health and the painter's site

Rinsing and leftovers: wash water, containers, and what never goes down the drain

Separate contaminated waters and apply the mandatory treatment without risking an environmental offence.

Products, VOCs, health and the painter's site

Ladder and stepladder: where they are still permitted, and where it means a fall

Distinguish occasional tasks tolerated on a stepladder from situations requiring mobile scaffolding.

Products, VOCs, health and the painter's site

In occupied homes: residual odour, water-based products and room scheduling

Organise the rotation of rooms to renovate an occupied apartment without disturbing the tenants.

Products, VOCs, health and the painter's site

Paint blistering: chain of evidence, duty to notify and full liability

Document slab moisture before painting to formally clear your responsibility.