Rainwater drainage: gutters and downpipes: the execution reference

This section covers the sizing and fabrication of gutters and rainwater downpipes for pitched roofs. It is intended for foremen and site managers who must design or install watertight drainage systems, sized for 100-year rainfall, suited to frost and compliant with the drainage requirements of standard SIA 271 and standard SN EN 12056.

  • 10chapters
  • 22 000words
  • 6sections in the training course
  • 60chapters in total

Key values to remember 4

Norme SIA 271

5 mm/m

Recommended slope to ensure self-cleaning of the gutters

Norme SIA 271

500 mm

Maximum spacing of gutter brackets in exposed areas

Norme SN EN 12056

0.03 l/(s·m²)

Usual design rainfall intensity in Switzerland

Norme SIA 271

6 m

Maximum distance between two expansion slides on zinc or copper gutters

Technical scope and rules of the trade in rainwater drainage

Rainwater drainage on pitched roofs (CFC 224) covers all the fabricated metal elements and pipework connecting the sloping roof covering to the collection network. This scope includes collection at the eaves (suspended or recessed gutters), expansion joints, emergency overflows, and the vertical run through exposed or concealed downpipes down to the base of the stack.

Every installation must prevent blockage and backflow towards the roof structure. In accordance with the general principles of the Code of Obligations (CO), the contractor must immediately notify the client of any defect found in the fixing supports or in the planned drainage capacities.

Installation sequence and linking of the ten chapters

Building a rainwater drainage system follows a strict logic, from the hydraulic design through to the watertightness check before acceptance of the construction site.

  1. Sizing and calculation of cross-sectionsDetermine the effective cross-section of the gutter and the diameter of the downpipes according to the projected area and the reference rainfall intensity (standards SIA 271 and SN EN 12056).
  2. Support and geometry of guttersAlign the gutter bottom with a minimum slope, set the spacing of the brackets to prevent any sagging and provide for the expansion of the metal.
  3. Protection against overflow of recessed guttersInstall overflows sized to discharge water to the outside before it can penetrate the structure in the event of a blockage.
  4. Installation of downpipes and connection at ground levelFix the downpipes with bayonet clips, incorporate expansion sleeves, fit the shoe at the base, then connect to the inspection chamber with a trap or separator.
  5. Protection, maintenance and inspectionFit the gutters with frost protection (heating cables) and leaf protection (leaf guards), then carry out the sprinkling test under controlled flow.

Gutters and their overflows must be sized to discharge the design rainfall without pressurisation or infiltration towards the sub-roof.

Norme SIA 271

📘 Chapters in this section 10

Rainwater drainage: gutters and downpipes

Sizing a gutter: collected area, rainfall intensity and effective cross-section

Calculate the exact cross-section of a gutter according to the collected area and 100-year rainfall in Switzerland.

Rainwater drainage: gutters and downpipes

Gutter slope and support: hook spacing, deflection and standing water

Set the slope and the bracket spacing to eliminate sagging and standing water.

Rainwater drainage: gutters and downpipes

Recessed gutter: the overflow is not optional

Size and position the safety overflow to protect the roof structure from any infiltration.

Rainwater drainage: gutters and downpipes

Rainwater downpipe: brackets, expansion and cast-iron base shoe

Install rainwater downpipes with expansion collars and a reinforced shoe at the base of the run.

Rainwater drainage: gutters and downpipes

Connecting to the network: manhole, trap and separation of waters required in Switzerland

Carry out the mandatory separation of waters and fit the inspection chamber with a removable trap.

Rainwater drainage: gutters and downpipes

Frost in gutters: heating cable, installation and limits

Manage ice formation in the gutter using a self-regulating heating cable and a snow thermostat.

Rainwater drainage: gutters and downpipes

Leaves and needles: leaf guards, grilles and cleaning intervals

Prevent blockage of the outlets by means of leaf guards and schedule a cleaning plan.

Rainwater drainage: gutters and downpipes

Suspended gutter: overhang, position relative to the eaves line and splashback

Adjust the position of the suspended gutter below the eaves line to avoid backflow.

Rainwater drainage: gutters and downpipes

Rainwater harvesting: filter, overflow and separation from the drinking-water network

Connect a downpipe filter and connect a rainwater tank while preventing any backflow of water.

Rainwater drainage: gutters and downpipes

Water test of drainage systems: method, flow rate and inspection record

Carry out the sprinkling test at continuous flow to validate the watertightness of the joints at acceptance.