Skip to content
Website
🧱 CFC 274Gates, grilles and motorised closuresChapter 3 of 10 in the section

Swing gate: cantilever weight, hinges, wind load and sagging

After reading this chapter, you will be able to size accurately the fittings and pillars of a swing gate exposed to the weather. You will master the calculation of the forces exerted by the cantilever and by the wind on a solid leaf, as well as the essential positioning of ground stops to prevent any mechanical sagging over time.

Key takeaways

  • The cantilever of a two-metre leaf multiplies the tension on the upper hinge.
  • A solid infill turns the gate into a sail and generates destructive lateral thrusts.
  • The metal pillar must have sufficient moment of inertia to limit deflection under maximum load.
  • Ground stops at the open and closed positions relieve the pivots during violent gusts.

Understanding the mechanical forces of the cantilever and the sail effect

A swing gate leaf acts as a horizontal cantilever beam subjected to gravity. As soon as the width reaches two metres, the centre of gravity moves noticeably away from the axis of rotation. The self-weight of the steel-section structure, combined with the infill, applies a continuous overturning moment to the suspension components. The upper fitting takes a pure horizontal tensile force, while the lower fitting or the pivot socket takes a compressive force equal in absolute value, added to the entire downward vertical load. The smaller the vertical distance between the two hinges relative to the width of the leaf, the more the pull-out tension on the upper fixing increases exponentially.

The classic mistake is to neglect the effect of the weather. Installing a fully sheeted panel without openings creates a continuous exposed surface. During an episode of bise or foehn, the dynamic wind pressure turns the leaf into a veritable sail. Unlike the weight, which always acts in the plane of the gate whether closed or open, the aerodynamic load is applied perpendicular to the surface. For a solid leaf two metres wide and one metre eighty high, a moderate gust produces a thrust of several hundred kilos transferred instantly to the plate of the upper hinge and to the shaft of the pillar. If the pivot is not sized for these combined forces, the axis bends, the bronze or polymer wear bushings are crushed, and the leaf drops until it rubs on the floor covering.

Comparison of forces by width and type of infill for a leaf 1.80 m high
Leaf widthType of infillTension at upper hinge (weight)Lateral force under reference windMain risk without central stop
1.50 mBar infill, 80 % openLowVery moderateSlight play in the wear bushings
1.50 mSolid 2 mm steel sheetModerateHighOvalisation of the upper hinge housing
2.00 mBar infill, 80 % openMediumModerateVisible deflection at the free end when closing
2.00 mSolid sheet or privacy slatsVery highCriticalPull-out of fixings and twisting of the pillar

Sizing the mechanical connections and stabilising the gate at ground level

To ensure the durability of a wide leaf, light metalwork requires rigid section sizes and adjustable industrial hinges. Forget simple hinges screwed directly into a nylon plug or light gate pin hinges. On a two-metre leaf, the use of adjustable hinges with welded clevis and a high-strength steel threaded rod of at least M20 or M24 is unavoidable. This system allows millimetre adjustment of plumb at installation and makes it possible to compensate for slight later structural settlement without heavy dismantling. At the base, a pivot mounted on a sealed ball bearing or a case-hardened ball pivot socket set in the ground offers minimal friction torque, sparing the metalworker any warranty callback for seizing.

The steel tube pillar must have sufficient moment of inertia to resist bending. For a solid leaf two metres wide, a square tube of at least 120 by 120 millimetres with a wall thickness of 4 or 5 millimetres is the minimum for construction. If the support is masonry, the added metalwork plate must have a wide drilling spacing, fixed by chemical anchoring with anchor rods penetrating deep into sound concrete, clear of masonry edges to prevent the base material from spalling under the effect of the lever arm.

  1. Calculating the vertical spacing of the hingesSpace the fixing points on the gate post as far apart as possible. A vertical spacing greater than 1.40 metres drastically reduces the horizontal tensile force exerted on the upper plate.
  2. Installing the central ground stopFit a central stop in cast iron or galvanised steel in the middle of the threshold. In the closed position, the leaf engages in it, which immediately blocks the lateral bending caused by gusts and neutralises the torsional moment on the pillar.
  3. Fitting the opening stops at the end of travelAlways set a damping ground stop at 90 or 100 degrees of opening, located as close as possible to the free end of the leaf. Never let the hinges alone absorb the kinetic stop of the gate when thrown open by a gust of wind.
  4. Adjusting the mechanical preloadAdjust the upper clevis to give the leaf a very slight upward counter-camber during installation, thus anticipating the natural loading of the mechanical adjustments.

Reducing wind load and designing the leaf to limit the lever arm

On a swing gate with a single leaf two metres wide, the choice of infill directly determines the service life of the fittings and the frame. A fully sheeted panel acts as a rigid sail: under a stormy gust from the west on the Swiss Plateau, the peak dynamic pressure generates horizontal stresses that far exceed the self-weight of the structure. This perpendicular force applies severe torsion to the pivot post and deforms the tubular structure through mechanical fatigue at the corner joints.

To preserve the rigidity of the leaf without increasing the cantilever weight, the metalworker favours a welded frame in thick-walled steel tubes, reinforced by an intermediate crossbar and a diagonal stiffener working in tension. This gusset or diagonal tie transfers the gravitational loads from the low tip of the leaf directly to the upper hinge. The classic mistake is to clad an overly flexible frame with solid sheets fixed with self-drilling screws, creating permanent shear that makes the bottom crossbar deflect by several millimetres from the first seasonal cycles.

Comparison of forces and behaviour by type of infill for a leaf 2.00 m x 1.80 m
Type of infillAir permeability (%)Average surface mass (kg/m²)Torsional force on the pivotCantilever behaviour
Solid 2 mm steel sheet0 %16 to 18 kg/m²Critical in gustsRapid sagging without a counter-tie
Inclined louvre slats25 to 35 %12 to 15 kg/m²Medium, airflow deflectedModerate stability, monitor the play
Perforated aluminium sheet / laser cut40 to 50 %6 to 9 kg/m²Low, reduced turbulenceExcellent retention of end deflection
Widely spaced vertical bars (110 mm gap)75 to 85 %8 to 11 kg/m²NegligibleMinimal geometric deformation

Sizing the pillar, adjustable hinges and ground relief stops

Anchoring a heavy cantilevered leaf begins with the moment of inertia of the metal pillar. A standard square tube of light metalwork is not enough if it is simply plugged into an unreinforced concrete footing. The horizontal thrust exerted by the two-metre lever arm produces a permanent tensile stress on the upper hinge fixings. The tubular pillar must have a section and wall thickness suited to prevent any elastic bending under the static load of the leaf open at 90 degrees.

To allow millimetre adjustment over time, fixed weld-on pin hinges are ruled out in favour of two-way adjustable hinges with reinforced clevises and stainless steel pins mounted on self-lubricating bearings or ball joints. The upper hinge takes the entire horizontal tension pulling the leaf away from the pillar, while the lower hinge absorbs the compressive thrust and carries the vertical load. Locking nuts or lock nuts secured with sealing compound prevent the progressive loosening caused by wind vibration.

  1. Setting the pillar and anchor groutingPlace the steel tube pillar on its concrete base, adjust the plumb with a spirit level with a two-millimetre backward lean to anticipate the initial deflection, then inject the non-shrink grout or tighten the anchor studs to the prescribed nominal torque.
  2. Fitting and pre-adjusting the ball-joint hingesScrew the threaded rods of the hinges into the tapped bosses of the pivot post. Adjust the axis-to-pillar distance to the mechanical minimum in order to reduce the parasitic secondary lever arm that fatigues the plate weld.
  3. Fixing the central ground stop and the end stopSet a closing stop with a cast iron or galvanised steel guide ramp in the centre of the opening. The stop must have a chamfered profile that forces the bottom crossbar to rise by three to four millimetres when locking, thus transferring the end load directly into the foundation.
  4. Fitting the opening stops with damperInstall a ground stop at the maximum opening of the leaf, positioned at the outer third of the leaf and not against the pillar, to block the travel without creating a destructive shearing effect on the pin hinges during a sudden gust of wind.

Diagnosing defects, anchor repair and stabilising a sagging leaf

Faced with a sagging leaf that rubs on the threshold or with hinges torn out under the combined action of gravity and gusts, the metalworker first intervenes to secure access. The leaf must be propped without delay to relieve the pillar and avoid a sudden failure of the upper fixing. The assessment begins by identifying the root cause: elastic or plastic deformation of the pivot post, bending of the metal pillar, pull-out of the plugs or shearing of the hinge.

  • Checking the plumb of the pillar under load and unloaded using a precision spirit level.
  • Checking the integrity of the chemical or mechanical anchorages and looking for micro-cracks in the masonry.
  • Examining the upper hinge: wear play, damaged thread, bent clevis or ovalised eye.
  • Measuring the warping of the frame under wind and checking the deflection at the end of the leaf.

If the steel tube pillar bends under the dynamic load of a two-metre solid leaf, a simple hinge adjustment solves nothing. When the tube has insufficient moment of inertia, the metalworker must reinforce the post with a welded stiffener, inject a non-shrink expanding mortar grout with internal reinforcement, or replace the post with a hollow section of greater cross-section and thickness. In the case of loosening in a concrete or masonry pillar, the failed plugs are redrilled to a larger diameter to fit stainless steel threaded rods set in two-component resin, strictly respecting the edge distance.

To make the structure last, the leaf often has to be adapted to the climatic stresses of the site defined according to standard SIA 261. The metalworker proposes removing the solid sheets in order to install perforated sheets, louvre slats or an open bar infill, thus reducing the horizontal thrust by more than half. Finally, the addition of a central stop and a ground relief stop is essential: at the end of travel, this ground stop relieves all the hinges and neutralises the cantilever, transferring the dynamic stresses directly to the masonry of the threshold.

Frequently asked questions

How can a heavy swing gate be relieved without completely redoing the concrete threshold?

Fitting a relief skid or a spring-loaded wheel fixed at the bottom end of the leaf makes it possible to transfer part of the self-weight directly to the ground. However, the wheel requires a perfectly trafficable and even surface. A reliable metalwork alternative is to fit a chamfered receiving stop under the lock and a diagonal strut with an adjustable tie to straighten the squareness of the frame without demolishing the existing foundations.

Why does an upper hinge snap cleanly in a violent gust of wind?

The closed leaf is subjected to a horizontal force proportional to its solid area. Under a gust, this thrust acts with a lever arm equal to half the width of the leaf, creating a maximum pull-out moment on the upper hinge. The metal works in repeated tension and mechanical fatigue. If the hinge pin has a thread notch with no radius or a steel of low strength class, shear failure becomes inevitable.

What is the minimum open area recommended to avoid the sail effect?

An open area of at least thirty per cent considerably reduces the pressure exerted by the wind on the leaf. In metalwork, incorporating perforated sheets with round or oblong perforations, or spacing tubular sections evenly, allows air to pass through the structure without creating a sudden suction at the back. This limits repeated oscillations, avoids local buckling of the facing sheets and durably protects the threads of the pivoting hinges.

What role does the ground stop play in the service life of the pin hinges?

The central ground stop with guiding chamfer relieves the cantilever in the closed position. As the closing stile of the leaf engages on this stop, it rises by a few millimetres, which cancels the permanent tensile stress on the upper hinge. In addition, the end-of-travel stops absorb kinetic energy during gusts, preventing the leaf from banging and hammering the rotating mechanisms.

Texts and standards cited

  • SIA 261Actions on load-bearing structures, in particular the determination of wind forces on walls and closures.

In the same section