Skip to content
Website
🧱 CFC 281Levelling compounds, industrial floors and screeder safetyChapter 7 of 10 in the section

Rinsing water: alkaline laitance, settling tank and drainage prohibition

End-of-shift rinsing of a screed pump produces loaded and highly basic residues. This chapter details the neutralization of the alkalinity of washing water, the installation of a mobile settling tank on the mixing platform and the evacuation of solid sludge according to the OLED, without any discharge into the communal network.

Key takeaways

  • Equipment washing water reaches a basic pH that destroys drainage networks.
  • Direct discharge of laitance into pipes or soil constitutes a severe environmental offense.
  • The baffle settling tank effectively separates solid matter from residual aqueous phases.
  • Dehydrated sludge must be handled and disposed of according to the mineral waste channels of the OLED.

Understanding the alkalinity of rinsing water and the risk of illegal discharge

At the end of the day, washing the mixing drum, compressor, hopper and delivery pipes generates hundreds of litres of water laden with fine particles. Whether it is a cement-based or anhydrite fluid screed, the dissolution of binders massively releases hydroxide ions. This chemical phenomenon drives the pH potential to levels between 11.5 and 13, turning this wash water into a highly corrosive effluent.

Any direct discharge into rainwater grates or the natural environment is prohibited. These collectors discharge unfiltered into watercourses, where basic water immediately destroys fish fauna and benthic flora through caustic burns. Towards the wastewater network, sulphates from an anhydrite screed or the basicity of the cement disrupt the purifying bacteria of the municipal wastewater treatment plant. Cantonal water police and municipal services carry out visual checks and spot sampling when the mixing plant is installed.

Screed laitance
Aqueous suspension composed of quartz fines, hydraulic binder residues or calcium sulphate, characterized by a very high pH value and a rapid tendency towards clogging sedimentation.

Organizing the settling tank and sludge disposal chain

To comply with Swiss environmental requirements, the installation crew must set up a dedicated sealed cleaning area as soon as the screed pump is delivered. The pipe purge effluent and machine cleaning must be entirely captured by a mobile settling tank placed on the ground. Two- or three-compartment systems separated by siphoned partition walls slow down the liquid flow velocity and allow suspended matter to settle by gravity to the bottom of the first compartment.

  1. Containment of the purge zoneInstall a sealed metal tank or a large retention container under the drum outlet and direct the jet of the pipe cleaning ferret directly into this volume.
  2. Settling of heavy particlesAllow the liquid mixture to rest overnight without agitation to promote the settling of the mineral paste and clarify the surface.
  3. Check and neutralization of the supernatant liquidMeasure the pH of the clear water with a test strip and dose a mild neutralizing agent if discharge into the wastewater network is authorized by the municipality.
  4. Dredging and drying of sedimentsEvacuate the accumulated sludge manually or by pumping into a closed rubble skip or sealed bags for handling.

Once the clarified water has been separated, the residual paste cannot be left on the plot or spread at the foot of the earthworks. The Ordinance on the Limitation and Elimination of Waste strictly regulates sorting at the place of production. Solidified rinsing sludges are classified as mineral construction waste. They must be dried before being sent to an appropriate controlled landfill or integrated into inert mineral material recycling channels, with the corresponding supporting documents required by site management.

Chemical neutralization and analytical control before discharge of liquid effluents

Cleaning the mixer and delivery pipes of a screed pump produces volumes of highly basic loaded water. Water contact with cementitious binders or calcium sulphates dissolves hydroxides and generates rinsing water alkalinity where pH frequently exceeds 12. At this level of basicity, direct discharge into the ground, into a rainwater collector or even into the municipal sewer is prohibited by federal water protection legislation. Caustic substances destroy the bacterial flora of treatment plants and cause immediate corrosion of concrete collectors. The screed contractor has the obligation to retain all these volumes within the work area.

The first treatment step relies on the on-site settling tank, which separates the heavy fraction from the colloidal fines in suspension. However, mechanical sedimentation alone does not change the basicity of the supernatant liquid in any way. Chemical neutralization is essential before any discharge into mixed wastewater. On Swiss construction sites, two techniques prevail to correct this imbalance without generating heavy metals or harmful salts: pressurized carbon dioxide diffusion and the measured addition of weak organic acids such as technical citric acid.

Comparison of pH correction solutions for screed rinsing water
Treatment processOn-site implementationTechnical advantagesPoints of vigilance
Carbon dioxide (CO2) injectionCompressed gas cylinder equipped with a pressure reducer and a porous sparger submerged in the tank.Total safety against under-dosing or acid over-dosing; pH stabilizes naturally around 7.5.Requires an electrical power supply or an autonomous system and the handling of heavy pressurized cylinders.
Technical citric acid powderManual dissolution and mixing with a lance in the clear water compartment of the tank.Packaging in lightweight bags, easy handling, product non-corrosive to the operator in case of splashing.Risk of excessive acidification if dosage is not measured with a strip or calibrated pH meter.
Concentrated hydrochloric acidDirect liquid addition to the container (method discouraged by cantonal services).Immediate action on very large volumes with a very reduced consumable cost.Release of toxic vapors, risk of severe chemical burns for personnel, frequent exceeding of the acid threshold.

Each tank emptying operation is subject to systematic control using a portable electronic pH meter or calibrated litmus paper strips over a range of 5 to 10. The team leader logs the measured value in the site operating log or tracking book. If the purified and neutralized water reaches the required level, it may be admitted into the wastewater network in agreement with site management and the local water service. Infiltration into permeable ground or discharge into a surface watercourse remains totally prohibited, even after neutralization.

Tank dredging, residue drying and disposal channels according to the OLED

Pumping residue sedimentation generates a compact and viscous mass at the bottom of the tank. Fine sand, quartz, anhydrite and cement hydrate particles form heavy laitance that quickly clogs the decanter compartments. As soon as sediments occupy one third of the useful volume, dredging is required to prevent fines from passing into the overflow compartment. The disposal of laitance sludge follows a structured process that separates the draining phase from the transport phase.

  1. Pumping and draining of materialsThe supernatant liquid is neutralized beforehand and then withdrawn. The remaining thick sludges are extracted using a mechanical shovel or manually into permeable geotextile dewatering bags placed on a sealed area connected to the tank.
  2. Setting and hardening of sludgeCement and anhydrite laitance dewaters in the open air to achieve a solid consistency similar to rock debris or a pelletable filter cake.
  3. Loading and containment in skipSolid and dried blocks are evacuated into a specific skip for inert mineral waste, protected by a tarpaulin to prevent leaching under heavy rain.
  4. Transport channel and traceabilityAn approved carrier transports the materials to a cantonal mineral sludge treatment centre or a recycling centre. Weighing and discharge slips are kept by the contractor.

When the restricted space of an urban construction site does not allow the installation of a sludge drying area, the company commissions a combined jet-suction vehicle. This truck vacuum-suctions the muddy mixture without spilling a single droplet on the ground. Effluents are then transferred directly to a cantonal station specialized in the physico-chemical treatment of industrial water. Although more expensive for the screed contractor, this logistics guarantees absolute compliance with environmental protection rules and eliminates any risk of clogging the municipal network.

Rinsing incident management and on-site emergency procedures

An accidental discharge of laitance into the clear water drainage network or onto natural ground constitutes an immediate environmental impact. The alkalinity of a screed pump's rinsing water, often higher than a pH of twelve, destroys aquatic fauna and clogs public pipes. As soon as a leak, an overflowing on-site settling tank or a misoperation during pipe cleaning is noticed, the site manager must stop operations to contain the incident.

  1. Pipe blockingPlace an absorbent boom or an inflatable mechanical plug in the downstream manhole to block the transit of sludge towards the public collector.
  2. Emergency pumpingVacuum up the alkaline liquid mixture accumulated upstream of the barrier using a lifting pump directed towards a temporary sealed retention tank.
  3. Neutralization and controlMeasure pH using test strips and correct by controlled injection of citric acid or carbon dioxide.
  4. Authority notificationNotify site management and the cantonal water protection service if the effluent has crossed the construction site perimeter.

The disposal of laitance sludge recovered after tank dredging must follow the appropriate channel. These solid residues must not be buried on site or abandoned in a mixed skip. In accordance with OLED requirements, the screed contractor has these dried mineral sediments transported to an approved treatment center or a controlled landfill, with a construction waste tracking slip certifying the volume evacuated.

Frequently asked questions

Can neutralized water from a settling tank be emptied into municipal sewers?

Discharge into the wastewater network remains subject to prior authorization from the municipality and the local treatment plant. Water must exhibit a stabilized pH between six and a half and nine, as well as controlled turbidity without suspended sediments. Discharge into the rainwater network remains strictly prohibited, even after chemical neutralization of alkalinity on site.

How to treat loaded water if the construction site has no accessible sewer?

In the absence of an authorized municipal connection, alkaline effluents must operate in a closed circuit. Water clarified in the settling tank is reinjected for the initial pump pipe cleaning cycles. Excess volumes are pumped into a sealed cistern and entrusted to a company specialized in the transport and industrial treatment of mineral sludge.

Why does liquid screed laitance clog pipes so quickly?

Fluid screed based on cement or calcium sulphate contains very fine particles that decant slowly in suspension but sediment abruptly as soon as flow slows down. In the presence of stagnant water, these binders crystallize at the bottom of pipes, forming an indurated crust impossible to dislodge with a standard high-pressure jetting machine, which requires complete replacement of clogged sections.

What to do with hardened sediments accumulated at the bottom of the settling tank?

Once water has decanted and been evacuated, thickened sludges are left in the open air for complete setting and drying. These solid mineral cakes are then shoveled out, sorted and disposed of as inert construction waste according to OLED guidelines. They must reach a recovery facility or a final storage channel with corresponding weighing slips.

Texts and standards cited

  • OLEDRules on sorting and disposal of mineral and special construction waste

In the same section